Product overview
Resolution
The resolution of measured values and raw values depends on the parameters "Measuring range" and
"Sampling rate". The table below shows how these parameters influence the resolution:
Measuring range
Sampling rate /
EtherCAT cycle time
±2 g
≤ 1 kHz /
≥ 1 ms
±4 g
±8 g
±16 g
±2 g
> 1 kHz /
< 1 ms
±4 g
±8 g
±16 g
The setting of the "Measuring range" and "Sampling rate" parameters is described in the chapter Settings
[} 25].
Additional tests
The devices have undergone the following additional tests:
Test
Vibration
Shocks
12
Explanation
10 frequency sweeps in 3 axes
5 Hz < f < 60 Hz displacement 0.35 mm, constant amplitude
60.1 Hz < f < 500 Hz acceleration 5 g, constant amplitude
1000 shocks in each direction, in 3 axes
35 g, 11 ms
Version: 1.4
Resolution
Raw values
10-bit
8-bit
Measured values
4 mg
8 mg
16 mg
48 mg
16 mg
32 mg
64 mg
192 mg
EP3752-0000