Specifications; Frequently Asked Questions - Vent-Axia Lo-Carbon Calido Installation & Operation Instructions

Mvhr unit
Table of Contents

Advertisement

 
Model Name
Ref Number
Model type
Voltage / Frequency
Free blowing capacity
Power consumption
When the heater is on
Sound pressure level [dB(A)] 3m
Heat recovery efficiency
Leakage
Motor type
Encloser class
Insulation class
Certified
Other labels
Filter
Unit wight
Installation
* Only exhaust blowing
Troubleshooting and disposal
Troubleshooting
If your Calido unit is not functioning properly, consult the following troubleshooting table. If the fault persists,
contact your supplier, distributor or the technical service department
Fault
Ventilation unit
without supply air
operation.
Noises
LEDs on front plate
do not illuminate
Orange Maintenance
indicator light
flashing
Low airflow
 
[V] [Hz]
[m³/h]
30
[W]
8,3
[W]
< 375
19
[%]
80
[%]
 
[kg]
Possible cause
Dehumidification set too low. Calido in
exhaust air mode.
Main module is not secured correctly.
Unit not switched on.
Power circuit interrupted.
End of maintenance interval has been
reached.
Filters contaminated or defective.
Lo-Carbon Calido
411133
Standard with pre heater
230VAC 50Hz
52
14,4
< 375
22
78
5
DC motor
IP24
(class II)
Intertek
OA: G4 / RA: G4
9,5
Qualified installer
Remedy
Check the dehumidification level
and increase it if necessary.
Check mounting plate.
Align the main module correctly.
Switch on the unit
Check power cable.
Check circuit breaker.
Replace dust filters.
Press filter change button.
Replace dust filters.
Decrease the filter change interval.
20
78
90 *
21,7
25
375
 
29
35
75
 
D