Safety instructions for the installer

Safety instructions for the installer

The following instructions should be strictly observed in order to prevent injury to the
users and other people, or damage to property.
The symbols mean:
Do not
Make sure that you do this
Do not disassemble
Indicates fatal risks or risks of serious injury
WARNING
- Use this product at the rated voltage and frequency indicated on plate.
Indicates a risk of personal injury or property damage.
CAUTION
- Do not install this product where it could be directly exposed to water.
- Do not install this fan near cooking equipment.
- Do not install this product in places with excessive oil fume.
- The unit must be installed in such a manner that it will not fall from the
ceiling or wall and that the unit is screwed in.
- The product must be installed on a wall or ceiling that is strong enough to
hold the unit, otherwise the wall or ceiling must be reinforced.
- Be sure to provide an appropriate opening for air intake and exhaust.
- Consider the location of the intake air so do not risk that gas or other fuel
gases can follow the supply air into the home.
- The appliance is equipped with an isolator switch for disconnecting from
the mains.
The switch separates all poles that provide full disconnection under
overvoltage category III.
This switch must be included in the fixed wiring in accordance with the
cabling rules.
- Precautions must be taken to avoid the back-flow of gases into the room from the
open flue of gas or other fuel-burning appliances.
 