Command
Function
Matrix Status (continued)
View power supply voltages,
unit temperature, fan speeds
and power supply status
View temperature of the unit
View status of power
supplies (Primary, Redundant)
View fan speeds
View individual video input
signal status
View all video input signal
status per SFP
View LinkLicense
View virtual size
X!
KEY:
= Input number
X1(
= Video signal status
X2$
= Power supply voltage
X2%
= Temperature
X2^
= Fan speed
X2&
= Power supply status
X2*
= Maximum virtual video matrix size
Verbose mode
Set verbose mode
View verbose mode
NOTE:
Verbose mode will revert back to default in the event of a power cycle, disconnect from SSH client, or disconnect from the Ethernet.
X2)
KEY:
= Verbose mode
Timeout Ethernet data port
Set current port timeout
View current port timeout
X2!
KEY:
= Timeout
SIS Command
(Host to Device)
S/s
Verbose mode 2/3
E
}
20STAT
Verbose mode 2/3
E
}
21STAT
Verbose mode 2/3
E
}
22STAT
Verbose mode 2/3
E X!
}
LS
Verbose mode 2/3
E
}
0LS
Verbose mode 2/3
E
}
LELIC
36I
000
– Maximum number of inputs for your configuration (
0
= No video signal at input,
P
= Primary is listed first,
Degrees in Fahrenheit and Celsius (example: xx.xx
Revolutions per Minute (RPM) (example: xxxx
0
= Power Supply inactive/Not installed,
2
= Power Supply failed/Installed
InputxOutput
(
E X2)
}
CV
E
}
CV
0
= Clear/none (default for Ethernet),
2
= Tagged response for queries,
E
X2!
}
0*
TC
E
}
0TC
The number of seconds (each step = 10 seconds) before timeout on IP connections
1
65000
(min=
, max=
[default=
FOX3 Matrix Series Switchers • SIS Configuration and Control
Response
(Device to Host)
X2$
X2$
X2%
X2^
X2^
P
R
1
2
•
•
•
•
•
X2$
X2$
X2%
X2^
Sts00*
P
R
•
•
•
X2% ]
X2% ]
20Stat •
X2$
X2$
]
P
R
•
X2$
X2$
]
21Stat •
P
R
•
X2^
X2^
X2^
X2^
]
...
1
2
3
n
•
•
X2^
X2^
X2^
22Stat •
...
1
2
3
•
•
X1( ]
X!
X1( ]
In
•
X1(
X1(
X1(
]
...
1
2
n
X1(
X1(
X1(
]
In00 •
...
1
1
n
LinkLicense for KVM System Configuration and Control
If a LinkLicense is not installed, returns
X2*
X2*]
*
1
= Video Input signal detected
R
= Redundant is listed second
RPM
1
= Power Supply active/Installed,
80x80
) Example:
X2)]
Vrb
X2)]
1
= Verbose mode (default for RS-232),
3
= Verbose mode and tagged responses for queries
X2!]
Pti0*
X2!]
30
300
=
seconds]).
Additional Description
X2^
X2^
X2&
X2&
]
...
3
n
P
R
••
•
X2^
X2^
X2^
X2&
...
1
2
3
n
P
•
•
••
•
24x and 80x have 3 fans,
X2^
]
40x has 4 fans
n
160x has 6 fans,
320x has 9 fans,
560x has 15 fans,
840x has 24 fans
Each response is the video input status,
n
starting from Input 1 and
= highest
numbered installed input.
0
= untie)
F
C
• xx.xx
)
)
If no data is received during the timeout
period, the Ethernet connection closes.
X2&
]
R
]
]]
36
Need help?
Do you have a question about the FOX3 Matrix Series and is the answer not in the manual?
Questions and answers