J150 - Replacing The Viewing Glass - Index B400 Operating Instructions And Maintenance Instructions

Table of Contents

Advertisement

Maintenance Summary - 8 Years
J150
- Replacing the viewing glass
Orientation
Maintenance Instructions
B400
DIE150EN - 05.06.2019
If the viewing glass is damaged, it must be replaced. This is
necessary regardless of the extent of damage. Even with minimal
damage, the impact resistance of the glass can no longer be
guaranteed.
For safety reasons, it is recommended to obtain the viewing glass
directly from the machine manufacturer.
The viewing glass consists of three panes. the inner pane (i) made of tempered
glass, the central pane (m) made of polycarbonate, and an outer pane (a) made of
PMMA (polymethyl metacrylate). The inner pane (i) is relatively resistant. It can be
cleaned with any commercially available cleaning agents. Only the center pane (m)
is essential for the impact resistance of the viewing glass. The polycarbonate pane
is subject to natural aging and must therefore be replaced at regular intervals.
After replacing the inner viewing glass and after the installation activities are
complete, the glass it must be sealed on the inside of the work area door (S). It is
necessary to provide a suitable sealant. The sealant Terostat 930 is used at the
factory for this purpose.
Example: G200.2_Arbeitsraumtuere_01_1
a
Outer pane (design pane made of PMMA - polymethyl methacrylate)
m
Center pane (polycarbonate)
i
Inner pane (glass)
S
Silicone gasket
If sealing compounds from other manufacturers are used, their
equivalence must be guaranteed by the supplier or manufacturer in
writing.
81