Hydraulic Brakes
Max. hydraulic oil pressure
Min. hydraulic oil pressure
Max. hydraulic oil flow
Min. hydraulic oil flow
μ
ATTENTION! The hydraulic circuit for the brakes is different from the general hydraulic circuit.
Air Brakes
Max. pressure in pneumatic system
Min. pressure in pneumatic system
Max. flow in pneumatic system
Min. flow in pneumatic system
Voltage
The sprayer is designed for the following voltage only:
Voltage
12 V DC. Tolerance: -1.5/+3.0 V DC.
Tolerance for voltage
- 1.5 V / + 3.0 V
Current from tractor
40 A peak
Blade fuses on the sprayer 25 A *
* The blade fuses usually allow up to 50 A for a few seconds before blowing.
DANGER! If the tolerances for voltage are exceeded, the electrical system can fail. Risk of fire. Risk of defect or
malfunctioning components.
Power Consumption
Recommended tractor engine output are as follows.
Main tank volume (litres)
4500
5500
7000
• End of tractor requirements.

Hydraulic Motor for Liquid Pump

Hydraulic oil consumption
36 l/min
150 bar
120 bar
30 litres/min
10 litres/min
10 bar
6.5 bar
No limit
2 litres/min
Output (hp)
Output (kW)
115
85
130
96
150
110
8 - Technical Specifications
10.5
12
15.0
199