1.6.1.4 Indoor DC/DC Midspan PoE injector 30W
The indoor DC/DC Midspan PoE injector 30W characteristics are detailed in the following
table:
Description
Ethernet data rates
Number of ports
PoE compatibility
PoE Output Power
PoE Output Voltage
PoE Pin Assignment and Polarity
Input Power Requirements
Dimensions
Weight
Connectors
Indicator
Operating Ambient Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Regulatory compliance
Electromagnetic Emission
Immunity
Note 1: beware of the operating ambient temperature. Output power derating over +50°C is
critical and has to be carefully considered to insure proper supply of the Wirnet iBTS.
Classification
Internal Use
Confidential
Strict confidential
This document is the strict property of Kerlink and shall not be either copied nor sent without express
Kerlink – 1 rue Jacqueline Auriol – 35235 THORIGNÉ-FOUILLARD
Wirnet iBTS
Specification
10/100/1000Base-T
1
IEEE 802.3at
30 Watts over 4 pairs
55 VDC
54-57 VDC under all conditions
Data Pairs 1/2 (-) and 3/6 (+)
Spare Pairs 7/8 (-) and 4/5 (+)
DC Input Voltage: 36-72VDC
DC Input Current: 0.6A
65 mm (W) x 36 mm (H) x 140 mm (L)
200g
Shielded RJ-45, EIA 568A and 568B
Green LED 1: Input power "ON"
Green LED 2: Valid IEEE8-2.3at load detected and
connected "PoE PLUS"
Green LED 3: Valid IEEE802.3af load detected and
connected
-20°C to +50°C
Maximum 90%, Non-condensing
-25°C to +85°C
Maximum 95%, Non-condensing
RoHS
WEEE
CE
FCC Part 15, Class B
EN 55022 Class B (Emissions)
ESD: EN61000-4-2. Level 3
RS: EN61000-4-3. Level 3
EFT: EN61000-4-4. Level 2
Surge: EN61000-4-5. Level 3
CS: EN61000-4-6. Level 3
written authorization of Kerlink
Kerlink m2m technologies reserved rights
Document title : Installation and
Maintenance Manual
Version : 2.0
Author : SNI
Date : 04/12/2018
Page 77 / 221

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1loc868-1w868-eu

Table of Contents