4.6 Setting connections
Before setting all connections, ensure that the POE injector is not connected to the mains
supply.
The following pictures details all the Wirnet iBTS required connections, including power
supply cables, data cables, RF coaxial cables and earthing connections:
Several earthing cables, wires, tapes or ring tongue terminals are required to connect the
installation and the materials to earth for lighting immunity and electrical security:
 Earthing of the Wirnet iBTS mounting kit
 Earthing of the RF coaxial surge protection
 Earthing of the Ethernet surge protection
 Earthing of the outdoor PoE injector
A M8 ring tongue terminal is provided for earthing of the Wirnet iBTS mounting kit.
The earthing cables characteristics are detailed in §1.8.4.2.
Note: the earthing cables are not provided by KERLINK.
Classification
Internal Use
Confidential
Strict confidential
Figure 126 : connection settings of the installation
This document is the strict property of Kerlink and shall not be either copied nor sent without express
Kerlink – 1 rue Jacqueline Auriol – 35235 THORIGNÉ-FOUILLARD
Wirnet iBTS
4.6.1 Earthing
written authorization of Kerlink
Kerlink m2m technologies reserved rights
Document title : Installation and
Maintenance Manual
Version : 2.0
Author : SNI
Date : 04/12/2018
Page 182 / 221