The 1 m / 39.37" distance may be modified if trials carried out by the user deem this
necessary.
•
Using the grounding air hose, connect the gun to an air regulator that can supply
at least 3 bar / 43.5 psi.
•
Using the fluid hose, connect the gun fluid fitting to the pump. Tighten the fittings
firmly.
Note: In some particulars cases, if the air hose (4) is not conductive, the fluid hose
(3) must be conductive. One of the 2 gun hoses (air or fluid) must be conductive.
6.2
Installation diagram - Air pressure adjustment with or without
gauge at the gun handle
1 - P 0 : Pressure
7. Storage
Our equipment must be stored in its original packaging.
In case of prolonged storage, it is preferable to carry out preventive maintenance for all
lubricants before start-up.
Storage before installation
•
Storage ambient temperature 0 / +50 °C (32° F / 122° F).
•
Protect the complete unit from dust/dirt, water/condensation, moisture, vibration
and shock.
•
Do not remove the packaging until just before assembly.
Storage after installation
•
Protect the unit from dust/dirt, water/condensation, moisture and shock.
2 - Air hose
12
3 - P 1 : Pressure
measured at the
gun handle during
the operating (air
needles open)
4 – Guns, models
FStart
Gravity