ICP DAS USA I-7565 User Manual page 31

Usb/can converter
Hide thumbs Also See for I-7565:
Table of Contents

Advertisement

AsciiToHex(FF)
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Table 8: CAN/USB FIFO overflow flag list
AsciiToHex(O)
Bit 3
Bit 2
Bit 1
Bit 0
Example:
Command: S<CR>
Receive: !50000000<CR>
Obtain some current information on the I-7565 module. The
response will show the following results: CAN baud rate=250K,
CAN register= normal, CAN transmit error counter=0, CAN
receive error counter=0 and CAN/USB FIFO= normal.
I-7565 USB/CAN Converter User's Manual (Version 1.0, March/2007)
Table 7: CAN register list
Bus Off Mode
Error Passive Mode
Reserved
Overrun Buffer
Stuff Error General
CRC Error General
Form Error General
Acknowledgment Error General
Reserved
Reserved
USB FIFO Overflow
CAN FIFO Overflow
Description
Description