Chapter 6

Alarm connections

You can select a number of options for the response of the VIP to an alarm. In
case of an alarm, the VIP can establish a connection to a predefined IP address
(VCS hardware receiver or PC with receiver software) automatically. You can
enter up to 10 IP addresses which will be selected in sequence by the unit until a
connection is established.
Note
Sender and receiver must share the same subnet for connection set-up
(see page 58).
When assigning the profiles take into account that in case of alarm
connections and auto-connect always Stream 1 is transmitted (see
page 42).
Connect on alarm:
Select On, to establish a connection automatically to a specified IP address in the
event of an alarm.
With the setting Follows input 1, the VIP holds the automatically set up
connection to a remote location as long as an alarm signal is present at the alarm
input 1.
Number of destination address:
Here you assign the numbering for the IP addresses to be contacted in the event
of an alarm. The unit contacts the remote locations one after the other in the
numbered sequence until a connection has been established.
VIP 10
Configuring the Sender
49