Maintenance and care
6.2
Trouble shooting
ERROR
The clamping-power is not big enough,
the load is slipping out
(optional)
(optional)
(Adjustment of the opening width)
(optional)
(Property of material)
Unbalanced load
(Adjustment of the opening width)
(optional)
Automatic release does not work
mechanical (optional)
6.3
Repairs
Only persons with the appropriate knowledge and ability are allowed to repair the device.
Before the device is used again, it has to be checked by an expert.
6.4
Safety procedures
•
It is the contractor's responsibility to ensure that the device is checked by an expert in periods of
max. 1 year and all recognized errors are removed (→ see DGUV regulation 1-54 and DGUV norm 100-500).
•
The corresponding legal regulations and the regulations of the declaration of conformity must be
observed!
•
The expert inspection can also be done by the manufacturer Probst GmbH.
Contact us at:
service@probst-handling.com
•
We recommend affixing the inspection sticker "„Sachkundigenprüfung / Expert inspection" in a clearly
visible place (order no.: 2904.0056+Tüv sticker with year number) after the inspection has been done.
5720.0020
CAUSE
•
The grippers are worn
•
The maximum load is exceed
•
The actual opening width is not
correct
•
The surface of the material is dirty
or the material is not suitable /
allowed for this device.
•
The device is not loaded
symmetrically
•
The adjustment of the opening
width is not symmetrical.
•
Automatic release does not work
V3
REPAIR
•
Replace the grippers
•
Reduce the weight of. the load
•
Adjust the opening width
according to the load you want to
transport
•
Check the surface of the material
or ask the manufacturer, if you the
material is allowed for this device.
•
Adjust the position of the load
•
Correct the adjustment of the
opening width
•
Clean automatic release with high
pressure-cleaner
•
Oil the automatic release (never
with grease)
•
Correct faulty switching (→see
chapter "Picture of the automatic
release")
•
Change the inset of the automatic
release
14 / 15