Page 1
Technical data and specifications mentioned in this manual are subject to amendment without prior notice. EN (Original Instruction) 9124500 / 2005 Reproduction of this service manual, Without the express written consent of Fri-Jado, Is prohibited. Page 1 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 2
All rights are reserved and nothing in this manual may be reproduced and/or made public in any way. Modifications: In case of unauthorized modifications in or on the unit, every liability on the part of the manufacturer becomes null and void. Rev 3 Service Manual MCC Hot / Cold 2021 Page 2...
Page 3
14.0 Exploded view MCC Cold (Self Serve) 15.0 Recommended spare part list MCC 16.0 Electrical schematic MCC Hot (Self Serve) (One Phase) 16.1 Electrical wiring MCC Hot (Self Serve) (One Phase) 16.2 Electrical schematic MCC Hot (Self Serve) (Three phase) 17.0 Electrical schematics MCC Cold (Self Serve)
Page 4
SAFETY Clean Hands and/or Tools Suggestions and recommendations. Notification Cleaning Take care off: On regularly interval Recycling symbol. Reading Instructions referred to Minimum room floor area. Part of manual under construction Pictures or photos to be added Rev 3 Service Manual MCC Hot / Cold 2021 Page 4...
Page 5
The shelves, glass and back of the hot unit can get hot. • All units must be cleaned regularly to ensure proper functioning. • Do not store explosive substances; such as aerosol cans with flammable propellant in this appliance. Page 5 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 6
Always keep the unit in upright position. 1.4.4 Outdoor use restrictions WARNING To avoid short-circuiting, the units may not be used outdoors nor in a rainy or very moist Environment. Rev 3 Service Manual MCC Hot / Cold 2021 Page 6...
Page 7
Service and technical support The electrical schematics of the unit are included at the end of this manual. In case of malfunctions which are not fixable by you, you can contact Fri-Jado. Make sure you have the following data available: •...
Page 8
One LED-module per level provides lighting of the products. Lighting and cooling are switched on simultaneously Self-serve models can be fitted with an optional night curtain. Air flow Self Serve Air flow Full Serve Rev 3 Service Manual MCC Hot / Cold 2021 Page 8...
Page 9
Accessories. Use the unit in perfect technical condition only. Page 9 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 10
2.6 Technical description Full Serve Hot Humidified The MCC Hot FS is a multilevel serve over heated display cabinet intended for hot presentation of food products. A heating element and an array of fans are located in the base of the unit and circulate hot air throughout the cabinet, creating uniform holding conditions.
Page 11
Hand filling system Automatic filling system Complete build up structure of the MCC hot Full serve Hot air flow Full Serve Page 11 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 12
Remove the front and rear boards. Remove both side boards. Lift the unit from the support beams using a pallet truck or forklift. Remove the supporting beams. Observe the safety and warning signs. Rev 3 Service Manual MCC Hot / Cold 2021 Page 12...
Page 13
Position the doors with the handles to the outside and with the warning sticker above the handle. Top Hinge Bottom Hinge Assy front door MCC 90 SS = 9380104 Complete set to order = 9389832 Page 13 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 14
If both hinge pins are correctly clicked into the bottom and upper hole, the door is mounted correctly. Rev 3 Service Manual MCC Hot / Cold 2021 Page 14...
Page 15
Cold units have been designed to operate at climate class 3 (according ISO 23953). • Hot units should not be used below 20 ºC (68 ºF) ambient temperatures. • Keep the plinth free from any obstacles to ensure ventilation. Page 15 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 16
(II and III) by changing the positions of the LED-armature with respect to the rear. Examples: For repositioning details refer to User manual Hot SS models The glass shelves can be positioned at two angled positions (0º and 3º). Refer to user manual. Rev 3 Service Manual MCC Hot / Cold 2021 Page 16...
Page 17
Water connection for automatic fill, Refer to user manual 3.6.1 Water Manually fill, Refer to user manual 3.6.2 Plateau Options On all MCC models, except the MCC Hot SS, the bottom presentation deck can be set at a variety of horizontal levels. Refer to user manual...
Page 18
Secure the side plinths by inserting the pegs into the slots of the front plinth, while clamping the front plinth to the front adjustable legs. Result Rev 3 Service Manual MCC Hot / Cold 2021 Page 18...
Page 19
Evaporation tray must be placed with the serial number label faced to the back of the unit. Label must remain visible (readable) (see drawing below) Connect power cord of evaporator tray to outlet on electrical box of MCC unit. Page 19 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 20
Circuit diagram evaporator tray Rev 3 Service Manual MCC Hot / Cold 2021 Page 20...
Page 21
Wiring diagram evaporator tray Page 21 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 22
• The maximum loading height is 50mm (2 inch) below the bottom of the shelf/air guide above. • The maximum carrying-capacity per shelf is 30 kg/m (66 lbs/m), by equal load. Rev 3 Service Manual MCC Hot / Cold 2021 Page 22...
Registration form. MCC Drop in Unpack instruction 9124590 For installation guide, refer 5.6 The MCC Drop in will be delivered, packed in a crate Start unpacking by removing top cover Page 25 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 26
Remove short sides first (Left and Right), by unscrewing them. Next, remove front and back panel, they are also screwed onto the support beams under the unit. Keep the support beams for further use. Rev 3 Service Manual MCC Hot / Cold 2021 Page 26...
Page 27
Keep strip in place during placing process. Keep wooden support beams for further usage. After lowering the cabinet into the cut-out in the counter top: Remove tie-wrap which is holding the power cord. Page 27 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 28
Make sure the shelf holders are placed in the required sleeve, for the wanted angled or straight position of the shelfs. Shelf rails of top shelf should be placed in lowest position. Shelf rails of middle shelf should be placed in highest position Rev 3 Service Manual MCC Hot / Cold 2021 Page 28...
5.2 MCC Cold Drop-in Specifications Self Serve Rev 3 Service Manual MCC Hot / Cold 2021 Page 30...
Page 31
Air intake and Air outlet are not allowed to interfere. A physical barrier must be placed in between the two air flows. Air inlet and air outlet surfaces must comply with the specifications, (see previous page) Page 31 Rev 3 Service Manual MCC Hot / Cold 2021...
Air intake and Air outlet are not allowed to interfere. A physical barrier must be placed in between the two air flows. Air inlet and air outlet surfaces must comply with the specifications, (see previous page) Rev 3 Service Manual MCC Hot / Cold 2021 Page 32...
• All warning signs/labels, minimum floor area label and Data plate must remain visible after installation. • Operation of the appliance must be accessible. Page 33 Rev 3 Service Manual MCC Hot / Cold 2021...
Step 2. Lift the cabinet from below, using stable filler blocks and remove the wooden support beams Page 35 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 36
Apply sealant or a thin flexible foam seal around the cut-out in the countertop. Carefully lower the cabinet into the counter Step 4. Remove and discard the metal transportation frame. Rev 3 Service Manual MCC Hot / Cold 2021 Page 36...
Page 37
(refrigerated models only) Step 7. Install all remaining trim panels. Make sure ventilation openings have the correct size and the cabinet remains accessible for service and maintenance. Page 37 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 38
Make sure, after build in, the cool engine is still accessible. Keep in mind the complete engine is extendable at the back side of the unit for maintenance and service purposes. Rev 3 Service Manual MCC Hot / Cold 2021 Page 38...
Page 39
6.0 Installation Front door section Page 39 Rev 3 Service Manual MCC Hot / Cold 2021...
Be careful to guide the rivet nut into the profile. Step 4. Slide square profiles into each other. Step 5. Place end cover on profile end. Step 6. Mount handle on glass door. - 1 - Rev 3 Service Manual MCC Hot / Cold 2021 Page 40...
Remove side glass (both sides) CAUTION: Once past the top guide, the glass pane might fall if not properly held Step 12. Remove side glass holder, depending on version. - 2 - Page 41 Rev 3 Service Manual MCC Hot / Cold 2021...
Remove screws (3x) to detach child guard from the bottom (recycle these screws to fix the bottom support!) Dispose of the child guard in accordance with local regulations - 3 - Rev 3 Service Manual MCC Hot / Cold 2021 Page 42...
Place nylon bearing in top column cover from below. Step 21. Put glass door in place. Very carefully, try to close the glass door(s). They are not adjusted in height yet, - 4 - Page 43 Rev 3 Service Manual MCC Hot / Cold 2021...
Also available in kit, 3701241 and 3701242 Height adjustment nylon washer set. See step 9. Height adjustment is done by repositioning the hinge on the glass, or adding the height adjustment washer(s). - 5 - Rev 3 Service Manual MCC Hot / Cold 2021 Page 44...
Page 45
Be careful to guide the rivet nut into the profile. Step 4. Slide square profiles into each other. Step 5. Place end cover on profile end. Step 6. Mount handle on glass door. - 1 - Page 45 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 46
Defrost function Function can be configured by the user Activates the Standby function (OFF) Opens Programming menu • • • Rev 3 Service Manual MCC Hot / Cold 2021 Page 46 (see parameter H32) (when outside the menus) Confirm commands •...
Page 47
The keypad locks automatically in the following situations: • On start-up, • After 30 seconds of inactivity. To unlock the keypad, press and hold for at least 3 seconds. Page 47 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 48
Switching off • Remove all products from the unit. In order to avoid temperature rise of the products, store them in another cooling unit. • Switch the cooling off. Rev 3 Service Manual MCC Hot / Cold 2021 Page 48...
Page 49
At a ambient temperature of 20 ºC (68 ºF) and an initial core temperature of 85 ºC (185 ºF) the factory settings of the unit’s temperature ensure a constant core temperature of at least 63 ºC (145.5 ºF) for 4 hours. Page 49 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 50
Press SET to access the “o61” parameter. • Press UP/DOWN to select an application. • Press SET to confirm, “o61” is displayed. • Continue to set the next parameters in the “cFg” menu. Rev 3 Service Manual MCC Hot / Cold 2021 Page 50...
Page 51
To ensure a good contact with the heated trays, only place a single layer of products. • The maximum carrying-capacity per shelf is 30 kg/m (66 lbs/m), by equal load. Page 51 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 52
For detailed cleaning instructions refer to User manual chapter 5 Examples: Cleaning possibility the top glass pane all units Cleaning possibility side pane all units Cleaning possibility off the top air guides Rev 3 Service Manual MCC Hot / Cold 2021 Page 52...
Page 53
Calibration 2 (Pb2) °C Calibration 3 (Pb3) °C Display mode during defrost Timeout value for display unlick Evaporator probe present flag firwarme rELease tAble of parameters Table of "installer" menu parameters Page 53 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 54
Fans ON time in night duty cycle secs*10 Fans OF time in night duty cycle secs*10 Alarms ("AL" folder) Parameters HAL and LAL Alarm differential °C Maximum temperature alarm °C Minimum temperatre alarm °C Rev 3 Service Manual MCC Hot / Cold 2021 Page 54...
Page 55
Cumulative door open time for disabling Energy Saving mode Offset on setpoint °C Intervention differential correction °C Duration of night mode hours Duration of fast cooling mode hours Night mode setpoint °C Page 55 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 56
Configurability of down key Configuratbility of ESC key Evaporator probe present flag Probe 3 present flag reLease firmware tAble of parameters Copy card ("Fpr" folder) Upload Format Copy Card Rev 3 Service Manual MCC Hot / Cold 2021 Page 56...
Page 57
Maximum value that can be assigned to the Setpoint °C Minimum value that can be assigned to the Setpoint °C Controller on time for faulty probe Controller off time for faulty probe Page 57 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 58
°C Probe Pb3 alarm activation differential °C Cool protection ("CPr" folder) Cool protection setpoint °C Cool protection differential °C Time that the temperature remains below the cool protection setpoint Rev 3 Service Manual MCC Hot / Cold 2021 Page 58...
Page 59
Password 1 Password 2 Display with decimal point Calibration 1 (Pb1) °C Calibration 2 (Pb2) °C Calibration 3 (Pb3) °C Display mode during defrost Timeout value for display unlick Page 59 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 60
Configurability of down key Configuratbility of ESC key Evaporator probe present flag Probe 3 present flag reLease firmware tAble of parameters Copy card ("Fpr" folder) Upload Format Copy Card Rev 3 Service Manual MCC Hot / Cold 2021 Page 60...
Page 61
Defrost stop temperature ° C Status of night operation Defrost Interval Compressor relay status Max. defrost time Firmware version readout Defrost delay at power up Drip delay Pagina 1 van 1 Page 61 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 62
Defrost stop temperature ° C Status of night operation Defrost Interval Compressor relay status Max. defrost time Firmware version readout Defrost delay at power up Drip delay Pagina 1 van 1 Rev 3 Service Manual MCC Hot / Cold 2021 Page 62...
Page 63
The refrigerant propane (R290) can create an ignitable gas/air mix, which can trigger an exothermic reaction in a critical mixing ratio with air and in connection with the respective ignition energy (ignition source). Page 63 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 64
Close the cover and place the screws in place or use the special key, which ever is Applicable WARNING No spark-forming components or components with a high surface temperature (according to IEC 60079-15) may be present in the substructure/counter where the unit is placed R290 Rev 3 Service Manual MCC Hot / Cold 2021 Page 64...
Page 66
Connect a temperature tester to the probe of the sensor for comparison. Test the probe with a Ohm tester (range 5kΩ til 100kΩ). Temperature Resistance kΩ ⁰F ⁰C +/- 500 Ohms 67,77 42,47 27,28 17,96 12,09 10,00 Rev 3 Service Manual MCC Hot / Cold 2021 Page 66...
Page 67
In the following table, you will be able to see all the possible alarms. The following table shows the alarms that the application can generate along with its description. Page 67 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 68
. key for longer than 5 seconds. It is only activates if the temperature conditions are fulfilled. Otherwise, the display will flash three times to indicate that the operation will not be performed. EWPlus EO LVD 5/12 Rev 3 Service Manual MCC Hot / Cold 2021 Page 68...
Page 69
Reserved: read-only parameter Note: ** The USER menu parameters also include 'PA2', which can be used to access the Installer menu. EWPlus EO LVD 6/12 Page 69 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 70
Fans OFF time in duty cycle. Fans used in duty cycle mode; valid when 0 ... 250 secs*10 FCO = dc and H42=1 (Pb2 probe present) EWPlus EO LVD 7/12 Rev 3 Service Manual MCC Hot / Cold 2021 Page 70...
Page 71
Duration of night mode 0 ... 24 hours dFt Duration of fast cooling mode 0 ... 24 hours SPn Night mode setpoint LSE ... HSE °C/°F EWPlus EO LVD 8/12 Page 71 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 72
• To modify the status of a specified function press the ‘set’ button • If the unit is switched off, the function labels go back to their default status. EWPlus EO LVD 9/12 Rev 3 Service Manual MCC Hot / Cold 2021 Page 72...
Page 73
Temp. ≤ HAL - AFd * if LAL is negative, Set + LAL < Set ** if HAL is negative, Set + HAL < Set EWPlus EO LVD 10/12 Page 73 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 74
1. No water intake / Not filled by hand 2. No water intake, supply not open 3. No water intake, inlet valve blocked, or defective 4. No water, or too much water, Water level sensor Rev 3 Service Manual MCC Hot / Cold 2021 Page 74...
Page 75
Electronic thermostat Display does not light Wiring Check wiring The unit is not reaching Loose sensor Check sensor the set temperature Thermostat Replace thermostat Malfunction Thermostat setting Check parameters Page 75 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 76
Water intake Not filling of Water supply closed Open water supply (Hot FS only) Humidification tray Inlet Valve Check, clean or replace Contaminated of Clean or replace water level sensor Rev 3 Service Manual MCC Hot / Cold 2021 Page 76...
Page 77
Page intentionally left blank Page 77 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 78
TX15 Depending on the length of the unit, there are 4, 6 or 8 screws. When refitting the glass, make sure the silicon protection profile is on. Rev 3 Service Manual MCC Hot / Cold 2021 Page 78...
Page 79
Before sliding the new pane into the rails, ensure the transparent sides of the pane are facing forwards and up. Slide it all the way back till the front of the pane is in line with the front plating. Page 79 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 80
Left and right side. Remove rail cover, loosen mounting screws and pull cover backwards. Screws Remove rail stopper (two screws on top). Remove sliding door(s). Replace in reverse order. Rev 3 Service Manual MCC Hot / Cold 2021 Page 80...
Page 81
Left and right side. Remove Rail cover, four screws, on top of rails screws two left and two right. Remove rail stopper Remove sliding door(s). Replace in reverse order. Page 81 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 82
Remove fan box. (see 11.9). Unscrew the sensor holding plate. Click sensor out of mounting bracket. Place new sensor, put wiring in the same location as the old wiring . Rev 3 Service Manual MCC Hot / Cold 2021 Page 82...
Page 83
11.6 Sensor Replacement (Cold Unit) Defrost sensor Under construction Air out sensor Under construction Page 83 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 84
MCC Air guide replacement Air guide replacement For replacement, open top glass pane entirely. Be aware of the weight of the glass. Remove the air guide by simply lifting them out. COLD Rev 3 Service Manual MCC Hot / Cold 2021 Page 84...
Page 85
Note: If replacement has to take place on a solid back unit, the back panel assembly must be removed before accesing the air box screws mentioned in step 1 Page 85 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 86
Lift out glass pane, starting lifting from the back. (Take care of glass holder strip on the front side of the glass) Take new glass pane, place front glass holder strip and place pane into position. Rev 3 Service Manual MCC Hot / Cold 2021 Page 86...
Page 87
Now you can pull the box toward you. The box will slide in its rails Normal version (24V psu) Special version (15V psu) See serial number remarks in parts section Page 87 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 88
11.13 Heating element replacement Remove Shelf Glass pane (refer 11.10) Remove air box (refer 11.9). Remove side glass (refer 11.2) Remove column cover (middle left column cover, seen from back of unit). Rev 3 Service Manual MCC Hot / Cold 2021 Page 88...
Page 89
Place new controller, by pushing it in. Connect wires again, to the marked positions (point 2 and 3) Check all parameter settings according the parameter list.(Chapter 9) Page 89 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 90
Open the air box by removing the closing screws Take out the faulty fan, and replace. Use new waterproof connectors to connect to the wires. Replace is reverse order. Rev 3 Service Manual MCC Hot / Cold 2021 Page 90...
Page 91
1. Lift top glass to” unlock” the front glass 2. Slightly turn the front glass towards you 3. In the right tilted position, you can take glass pane including prifile out. 4. Replace in reverse order. Page 91 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 92
50 Hz 50 Hz 50 Hz Power 0.48 kW 0.56 kW 0.67kW Refrigerant/GWP R290 / 3 R290 / 3 R290 / 3 Refrigerant charge 170 g 220g 270 g Rev 3 Service Manual MCC Hot / Cold 2021 Page 92...
Page 94
1053 mm 1053 mm 1053 mm Voltage 1N, 230VAC 1N, 230VAC 3N, 400 / 230 VAC Frequency 50 Hz 50 Hz 50 Hz Power 1,85 kW 3,02 kW 4,19 kW Rev 3 Service Manual MCC Hot / Cold 2021 Page 94...
Page 95
2 pole earthed plug 2 pole earthed plug 2 pole earthed plug Length power cord approx. 1,5 m 1,5 m 1,5 m Water supply pressure >150 kPa >150 kPa >150 kPa Page 95 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 97
MCC 150 Cold 1200 1500 MCC 150 Cold drop-in version Specifications and technical data are subject to amendment wi These are basic drawings. For more detailed technical information, please vi Page 97 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 98
Specifications and technical data are subject to amendment witho These are basic drawings. For more detailed technical information, please visit w 1500 endment without prior notice. www.frijado.com tion, please visit www.frijado.com. Rev 3 Service Manual MCC Hot / Cold 2021 Page 98...
Page 99
1N~ 230V 3N~ 400 / 230V 50 Hz 50 Hz 3,02 kW 4,19 kW MCC 60 Hot drop-in version MCC 90 Hot MCC 120 Hot MCC 90 Hot drop-in version Page 99 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 100
MCC 90 Hot drop-in version MCC 120 Hot 1200 Specifications and technical data are subject to amendment MCC 120 Hot drop-in version These are basic drawings. For more detailed technical information, please Rev 3 Service Manual MCC Hot / Cold 2021 Page 100...
Page 101
Specifications and technical data are subject to amendment w These are basic drawings. For more detailed technical information, please v 1200 amendment without prior notice. www.frijado.com rmation, please visit www.frijado.com. Page 101 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 102
MCC placed on wheels will alway need a floor seal (as seen on picture) in order to prevent warm outlet air being sucked in at the air inlet, condensor side.(back side of unit) Rev 3 Service Manual MCC Hot / Cold 2021 Page 102...
Page 103
Page intentionally left blank Page 103 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 104
13.0 Exploded view MCC Hot (Self Serve) Complete assy Rev 3 Service Manual MCC Hot / Cold 2021 Page 104...
Page 105
Fan Box Bottom MCC 90 9380058s number Fan Box Bottom MCC 120 9380074s Heating element 475x540 750W MCC 60 9382090 Heating element 775x540 1125W MCC90 9382093 Heating element 1075x540 1500WMCC120 9382096 Page 105 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 106
13.0 Exploded view MCC Hot (Self Serve) Complete assy Rev 3 Service Manual MCC Hot / Cold 2021 Page 106...
Page 107
Starting of serial number ..... use mentioned article numbers For serial number before use article numbers below Number Description Article number Quantity Fan box top shelf Fan box middle shelf Fan box bottom shelf Power supply Page 107 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 108
13.0 Exploded view MCC Hot (Self Serve) Rev 3 Service Manual MCC Hot / Cold 2021 Page 108...
Page 109
Child guard assy MCC120 9380019s Side panel 9384005 2 (see 75 ) Base end cover panel 9384021 Side glass MCC 9382030s 2 ( see 73 ) Plug top glass-pane 9263022 Page 109 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 110
13.0 Exploded view MCC Hot (Self Serve) 55 56 Rev 3 Service Manual MCC Hot / Cold 2021 Page 110...
Page 111
Fan box top shelf Fan box middle shelf Fan box bottom shelf 57 A Timing relays 30003932 57 B Relays 9290114s 9381019 Power supply Output voltage should be 16,7 Vdc Page 111 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 112
14.0 Exploded view MCC Cold (Self Serve) Rev 3 Service Manual MCC Hot / Cold 2021 Page 112...
Page 113
Side panel MCC 150 9384005 Side glass topside bracket 9384201 2 ( see 166 ) Back panel 90 9384007 Back panel 120 9384008 Back panel 150 9384009 Plug top glass-pane 9263022 Page 113 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 114
14.0 Exploded view MCC Cold (Self Serve) Rev 3 Service Manual MCC Hot / Cold 2021 Page 114...
Page 115
Compact fan 614 NN 30001330 5 - 9 Nut M4 0142307 Led driver EDXe 160/12.054 30007730 Compact fan 8414 NLU 9381015 5 - 9 Led Armature support bracket 9384091 Page 115 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 116
14.0 Exploded view MCC Cold (Self Serve) Rev 3 Service Manual MCC Hot / Cold 2021 Page 116...
Page 117
Condensor MCC 150 SS 9381008s required Condensor MCC 120 SS / MCC 150 FS 9381010s Condensor MCC 90 FS 9381021s Air flow cover Depending on version Check by serial number required Page 117 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 118
14.0 Exploded view MCC Cold (Full Serve) Rev 3 Service Manual MCC Hot / Cold 2021 Page 118...
Page 119
Product plateau MCC 90 400 mm 9384082 Product plateau MCC 120 9384125 Product plateau MCC 150 9384290 Fan plate MCC 90 9384080 Fan plate MCC 120 9384283 Fan plate MCC 150 9384284 Page 119 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 120
14.0 Exploded view MCC Cold (Full Serve) Rev 3 Service Manual MCC Hot / Cold 2021 Page 120...
Page 121
Side panel MCC 150 9384005 Side glass topside bracket 9384201 2 ( see 166 ) Back panel 90 9384007 Back panel 120 9384008 Back panel 150 9384009 Plug top glass-pane 9263022 Page 121 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 122
14.0 Exploded view MCC Hot (Full Serve) Rev 3 Service Manual MCC Hot / Cold 2021 Page 122...
Page 123
9382033s Front glass pane tilted forward MCC 90 9382029s Front glass pane tilted forward MCC 120 9382034s Front glass pane tilted forward MCC 150 9382123s Plug top glass-pane 9263022 Page 123 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 124
14.0 Exploded view MCC Hot (Full Serve) Rev 3 Service Manual MCC Hot / Cold 2021 Page 124...
Page 125
Element MCC 60 1500W 208V 9382175 Element MCC 90 1800W 230V 30002245s Element MCC 90 1800W 208V 9382176 Element MCC 120 2400W 230V 30002244s Element MCC 120 2400W 208V 9382177 Page 125 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 126
14.0 Exploded view MCC Hot (Full Serve) 55 56 Rev 3 Service Manual MCC Hot / Cold 2021 Page 126...
Page 127
See remark serial number End Clamp Clipfix 35-5 PHX 9191222 Dinn rail 923057 power cable 9091383 Cover Electonics box 9384095 PCB water level control 9181047s Valve inlet 2.5l.min 9261040s Page 127 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 128
9191239 Terminal PT 4 (GY) 9191240 End cover D=PT 4 PHX 9191223 Contactor AB100-C09KL400 3500069 Power supply 24VDC 40W 9381012 Soft close damper 3N 9281078 Steel roller bearing 9382100 Rev 3 Service Manual MCC Hot / Cold 2021 Page 128...
Page 129
End cover D=PT 4 PHX 9191223 Terminal PT 4 (GN/YE) 9191239 End Clamp Clipfix 35-5 PHX 9191222 Led driver EDXe 160/12.054 30007730 Compact fan 8414 NLU 30010348 5 till 9 Page 129 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 131
0142056 Lockwasher M8, SS 4285078 Nut 1/4" bsw ZP 9077004 Socket set screw M4x6, SS 9191049 Set screw M5x5, black 9301049 Circlips external ø25 4285010 Nut M3, ZP with lockwasher Page 131 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 132
4285414 Capnut, M4 ss 0149298 Spacer 10mm, Ø3,4x6 Nylon 0149299 Spacer 15mm, Ø4,2x8 Nylon 0251473 Washer M4, ZP ø4xØ16 4285043 Nut M5, prevailing torque SS 4280110 Bolt M6x20, SS hexagon head Rev 3 Service Manual MCC Hot / Cold 2021 Page 132...
Page 133
16.0 Electrical schematic MCC Hot (Self Serve) (One Phase) Schematics for: Serial number starting from serial number ....Page 133 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 134
16.1 Electrical wiring MCC Hot (Self Serve) (One Phase) Rev 3 Service Manual MCC Hot / Cold 2021 Page 134...
Page 135
16.1 Electrical schematic MCC Hot (Self Serve) (One phase and time relais) Schematics for: Serial number before serial number ....Page 135 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 136
16.1 Electrical wiring MCC Hot (Self Serve) (One phase and time relais) Rev 3 Service Manual MCC Hot / Cold 2021 Page 136...
Page 137
16.2 Electrical schematic MCC Hot (Self Serve) (Three phase) Page 137 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 138
16.2 Electrical wiring MCC Hot (Self Serve) (Three phase) Rev 3 Service Manual MCC Hot / Cold 2021 Page 138...
Page 139
17.0 Electrical schematics MCC Cold (Self Serve) Page 139 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 140
Rev 3 Service Manual MCC Hot / Cold 2021 Page 140...
Page 141
17.1 Electrical wiring MCC Cold (Self Serve) Page 141 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 142
Rev 3 Service Manual MCC Hot / Cold 2021 Page 142...
Page 143
17.2 Circuit Diagram MCC Hot (Full Serve) Page 143 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 144
17.3 Electrical wiring MCC Hot (Full Serve) Rev 3 Service Manual MCC Hot / Cold 2021 Page 144...
Page 145
Page 145 Rev 3 Service Manual MCC Hot / Cold 2021...
Page 146
Rev 3 Service Manual MCC Hot / Cold 2021 Page 146...
Page 147
Fri-Jado B.V. Blauwhekken 2 4751 XD Oud Gastel The Netherlands Tel: +31 (0) 76 50 85 400 Page 147 Rev 3 Service Manual MCC Hot / Cold 2021...
Need help?
Do you have a question about the MCC HOT and is the answer not in the manual?
Questions and answers