3. Confirm that the power is connected properly. The SYSTEM LED should be ON (see
g
NOTE
The installation of this product must comply with the national, state and local electrical code requirements, as applicable. The AC branch circuit
overcurrent protection must be a fuse or circuit breaker rated 125 VAC, 20 Amps maximum or 250 VAC, 16 Amps maximum. A readily accessible
disconnect device that is suitably approved and rated must be incorporated in the field wiring.
f
CAUTION!
It is recommended that an external AC Surge Protection Device be installed at the AC input connection to the local AC-Powered product. The Surge
Protection device should provide L-N, L-G, and N-G protection. It is also recommended that the device contains a visual 'GOOD' indicator.
f
WARNING!
This equipment incorporates double pole/neutral fusing. If the neutral fuse opens and the line fuse does not open, voltage could still be present in the
unit.
Install SFP+ Modules
You can install or remove an SFP+ module from an SFP+ port without having to power off the switch. To install an SFP+ module, complete the following
steps.
1. Insert the module into the appropriate SFP+ port.
2. Press firmly to ensure that the module seats properly into the connector.
4
Figure 6. Connecting the AC Power Cord
Figure 7. Installing an SFP+ Module into an SFP+ Port
"SYSTEM Status
LED").
617101568F1-13A