Setting The Eps Function - Sungrow SH5K-20 User Manual

1-phase hybrid inverter
Hide thumbs Also See for SH5K-20:
Table of Contents

Advertisement

User Manual
Settings
Password:
1 1 1

10.4.2 Setting the EPS Function

The reserved capacity is the on-grid minimum battery discharge level. The
reserved battery capacity will be supplied to the emergency loads in the off-grid
system.
EPS Setting
Disable
Enable
If the battery type is set to "Other Battery", it is not need to set the reserved
capacity.
If the EPS function is enabled, the buzzer inside the inverter will beep
intermittently for 20 s when the battery level is lower than the threshold value
specified in the following table.
Tab. 10-2 Threshold Values of Different Batteries
Battery Type
Sungrow (retrofitting system) / LG
BYD
GCL
Pylon (US2000B), TAWAKI
Lead-acid
Settings
1/6
EPS Setting
Existing Sys
Zero-export
Settings
4/6
Limit P Ramp
Load Control
Comm. Param
Settings
5/6
Active Power
DRM Switch
PT1000 Switch
Must install an
EPS box if the EPS
function is enabled!
SOC Threshold
≤ 6 %
≤ 11 %
≤ 16 %
≤ 21 %
≤ 45 V
10 Appendix I: LCD Operation
Settings
2/6
Battery Type
Bat Usage Time
Forced Charge
Settings
3/6
Earth Fault
Prot. Param
Reactive Power
Settings
5/6
Factory Reset
EPS Setting
Reserved Capacity
000 %
77