Page 30
Wall-mounting bracket Inverter Energy meter and CT cable Expansion plug set (x2) PV connectors (x2) AC connector set CAN cable (battery) Power supply cable (meter) RS485 cable (meter) Copper bar OT25-6 terminals M5 screws and washers Key to the front cover Documents...
Page 31
0.8 lead to 0.8 lag EPS Output Max. output power 5000W/5000VA Max. output power (battery mode) 3000W/5000VA Output voltage/frequency 230V/50Hz Ⅰ/ IP65 Safety Class/Enclosure -25℃...+60℃ Ambient temperature III[MAINS],II[PV][BATTERY] Overvoltage Category Grid Monitoring: AS 4777 SUNGROW POWER SUPPLY CO., LTD. WWW.SUNGROWPOWER.COM MADE IN CHINA...
Page 34
Min. Max. RH Max. +100% +60° C -25° C Flammable material or Flammable wall Closed Cabinet gas near the installation Snow Direct sunlight Direct rain fall accumulation...
Page 35
300mm 300mm Mark the positions Drill holes Note: ( 1 ) The depth of the holes should be about 70 mm. ( 2 ) Be sure to adhere to the following screw assembly sequence: self-tapping screw, spring washer, fender washer, bracket.
Page 40
PV system Meter Main link switch Solar switch Network Utility Sungrow meter meter grid Home Appliance Power supply cable RS485 cable Grid Load...
Page 48
Webserver Explorer Inverter Internet SolarInfo Bank server Inverter Router/Switch Remote Local access SolarInfo Moni APP Webserver Explorer SolarInfo Bank...
Page 54
BAT_Temp. PT1000 SH5K STB5K Meter Main Sungrow meter link switch Network Utility meter grid PV system Home appliance Emergency appliance Battery...
Page 55
² 10 mm-15 mm 40 mm-50 mm Grid Load SH5K AC Backup control cable DI cable...
Page 60
Start Press to enter the menu. Press to navigate through the menu. Press to confirm a selection. Modifying mode Selecting mode Press / to move Press / to move to the desired item. to the desired item. Press and the first digit of the Press to confirm.
Page 61
Q(p): Characteristic PF curve for Q(u) power resopnse mode Battery Type Battery Type Battery Type Li-ion Pylon No Battery Li-ion BYD Set battery type and Li-ion Sungrow Li-ion GCL Lead-acid Narada parameters Li-ion LG Li-ion BlueSun Other Lead-acid Bat Usage Time Start Time1 00:00...
Page 68
Press Run Info ON / OFF 2000 Settings Running 16:37 6 12 18 Scroll pages by pressing Input Mode Indep. Li-ion Sungrow 36.1° C Bat Tmp Bat Cap 4.8kWh Bat SOC 99.9% Self Csmp 89.9% Bat SOH CO2 Reduced 58kg...
Page 69
Menu 5000 2100 Press Run Info ON / OFF 2000 Settings Running 16:37 Press Menu Press hh : mm : ss Time Time 16 : 37 : 08 Country DD / MM / YY Date 22 / 02 / 15 Fault Record...
Page 84
Main Menu Run Info ON / OFF Settings Time Country Fault Record Password: 111 Password: 111 · Power curve · Daily energy · Total energy Reactive Power * Refer to 12.2 Reactive Power Regulation. · Battery info · Grid info Active Power ·...
Page 85
× → → hh : mm : ss Time 07 : 38 : 08 DD / MM / YY Date 22 / 02 / 15...
Page 86
× → → Country Password: 1 1 1 Country Country: [ AU ] Country Grid Standard “ ” Press Country: [ AU ] Manual Default Grid Standard Prot. Stage Vgrid-max 260.0V Press Press Vgrid-min 180.0V Single Stage Fgrid-max 52.00Hz Multi. Stage Manual Default Fgrid-min 47.00Hz...
Page 88
× → → Fault Record P1/1 15022708:55:27 15022707:11:21 × → → ON / OFF Restart Confirm ‘ON’? Confirm ‘OFF’? Confirm ‘Restart’?
Page 89
The DRM0 state will prohibit the 'ON'! × → → Settings Password: 1 1 1 Settings Settings Settings Load Control Reactive Power Off-grid Setting Active Power Bat Usage Time Comm. Param Zero-export Battery Type Forced Charge Settings Settings Prot. Param DRM Switch Existing Sys PT1000 Switch...
Page 91
× → → → → → No Battery ! Bat Usage Time Start Time 1 00:00 End Time 1 24:00 Weekday Usage 00:00 Start Time 2 Weekend Usage End Time 2 24:00 Weekend Usage Start Time 1 00:00 End Time 1 24:00 Disable Start Time 2...
Page 92
Forced Charge Start time1 00:00 End time1 00:00 Target SOC 100% Forced Charge Start time2 00:00 00:00 End time2 Target SOC 100% Forced Charge Time [ Weekday ] × → → → → → Load Control Timer ON/OFF Optimized Load Control Start Time1 09:00 09:30...
Page 93
Load Control ON/OFF Timer ON/OFF Optimized Grid Inverter DO port OFF mode COM1 Contactor DO relay Load Control Timer ON/OFF Optimized Optimized P2/2 Start time 09:00 End time 09:30 Power[W] 1000 ...
Page 94
Inverter 1000W DO port Grid 3000W COM1 DO relay Contactor 2000W × → → → → → − Addr 192.168.001.100 Press DHCP [ON] Sub Net: − Port 00502 255.255.000.000 Press − Gateway: DNS1 192.168.100.002 001.002.004.008 Press InfoBank [ON] DNS2 [ON] 008.008.008.008 ×...
Page 95
Battery Type Press No Battery Setting completed ! Li-ion Sungrow Li-ion LG Battery Type Li-ion Sungrow Press No Battery Tray Number Li-ion Sungrow Li-ion LG Battery Type Li-ion LG Press No Battery LG Generation I Li-ion Sungrow LG Generation II...
Page 96
Battery Type Only qualified pers- Press onnel are allowed Li-ion BYD adjust relevant param- eters. Improper setti- Lead-acid Narada ngs may cause damage Other Lead-acid to the inverter! 58.8 V Over Vtg 0.300 C Max. Chrg CSTVtgChrg 56.40 V Low Vtg 42.0 V Max.
Page 98
× → → → → → DRM Switch Disable Enable × → → → → → PT1000 Switch Disable Enable × → → → → → Menu ON / OFF Run Info ON / OFF Settings Factory Reset Confirm factory reset?
Page 100
Webserver Operating Parameters History Energy Information Settings Records Management Summary System Running Information Parameters Records Error Detailed Operating Records Information Parameters Protection Event Parameters Records Battery Parameters Communication Parameters...
Page 108
OverFrq Start 50.25 Hz OverFrq End 52.00 Hz Rated power of inverter Inverter power output prior to frequency disturbance Allowed ramp up rate once frequency has returned to 50.15 Hz for at least 60 s Inverter to disconnect Required power reduction of when f≤47 Hz inverter in response to exceeding 50.25 Hz to 52 Hz...
Page 109
Max. charge rate of energy storage Charge rate prior to frequency disturbance Allowed ramp up rate once frequency has returned to 49.85 Hz for at least 60 s Required reduction in charge change rate of inverter in response to frequency falling Max.