Job No. - Eleclc (Lighting Check); Job No. - Elechc (Horn Check); Job No. - Elecht (Horn Test) - Promax RR 14 EVO 2 400 Hybrid Operating & Maintenance Manual

Rail mounted mobile elevating work platform
Table of Contents

Advertisement

PAMP020RR
Revision 2
December 2019
Job No. – ElecLC (Lighting check)
Scheduled work
1
Check all lights for damage and illumination
While stationary, red marker lights should
2
illuminate at both ends
Whilst operating foot pedal and travel joystick,
for the selected direction of travel, the red
3
marker lights should turn off and the white
marker light and headlight should illuminate.
Job No. – ElecHC (Horn check)
Scheduled work
Activate button at operator position to sound
1
horn
With machine turned on, remove trailer plug
2
- Horn should sound
Replace plug and repeat at opposite end
Job No. – ElecHT (Horn test)
Scheduled work
Using a calibrated sound meter, take readings at
1
the specified locations around the machine.
RR 14 EVO 2 400 Hybrid
Arising work
Renew/report any non-functioning lights.
1
NB: Some warning lamps can only be checked by
a fitter under test conditions
Check switch at operator position for activation.
NB: This switch allows all white lights to be
2
illuminated at all times while in road mode.
In rail mode, this switch is inactive.
3
Check electrical connections
3
Renew/repair as required
Arising work
1
Do not use machine
1
Report to fitter/supervisor
1
Fitter only: Repair/renew
2
Do not use machine with trailer
2
Report to fitter/supervisor
2
Fitter only: Repair/renew
Arising work
Record readings for:
Low revs only
Low revs + horn
1
High revs only
High revs + horn
In the records section.