Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules
Product Specifications
Features
Lowest power dissipation of less than 2 W per
segment under full load condition.
Full balance of electric circuitry with high
isolation against radio frequency and in-band
interference.
High-integrity passive power conditioner
modules.
Local and remote alarm annunciation.
Tolerance against inrush currents during
segment start.
Full current span operation from
10 mA ... 500 mA.
Advanced diagnostic module for physical
layer fieldbus diagnostics.
2.2

System Components

2.2.1

Motherboard

MBHC-FB-4.GT*
The motherboard MBHC-FB-4.GT enables the supply of PROFIBUS PA 4 segments and the
connection to a fieldbus host system. 4 sockets hold the power supply modules, each
supplying 1 of the 4 segments. 1 dedicated socket holds the diagnostic module and another
dedicated socket holds the gateway from PROFIBUS PA to a host system.
MBHC-FB-4.GT: Simplex motherboard equipped with screw terminals
MBHC-FB-4.GT.1: Simplex motherboard equipped with spring terminals
2.2.2

Gateway Modules HD2-GTR-4PA*

Gateway HD2-GTR-4PA (Segment Coupler SK3)
The gateway is a FieldConnex
to PROFIBUS PA segments. The Segment Coupler makes each PA device appear as if it was
related to DP with regard to addressing, cyclic/acyclic data exchange, and transfer rate. The
gateway operates with power supply modules connected to the same or a separate
motherboard. The gateway provides a PA master for each segment and thus enables short bus
cycle times.
For details on the gateway, go to www.pepperl-fuchs.com and look up the corresponding
product information.
Gateway HD2-GTR-4PA.PN
The gateway is a FieldConnex
and integrates communication of 4 PA segments into PROFINET IO systems. The gateway
operates with power supply modules connected to the same or a separate motherboard. The
gateway provides a PA master for each segment and thus enables short bus cycle times.
For details on the gateway, go to www.pepperl-fuchs.com and look up the corresponding
product information.
User benefit
Long useful lifetime. High packing density and
reduced cooling requirements.
High resistance to external disturbance such
as EMI.
Long useful lifetime.
Easy maintenance and troubleshooting.
Long-term, robust operation with tolerance
towards field device misbehavior.
Flexible segment design and tolerance
against live working on field devices.
Improved and known quality of fieldbus
installation. Live real-time monitoring for
preventive and predictive maintenance.
Professional tools for easy fieldbus
troubleshooting.
system component for transparently coupling PROFIBUS DP
®
system component for coupling PROFINET to PROFIBUS PA
®
7