Updating Steps; Determining Current Blade Server Firmware Levels - IBM BladeCenter QS22 Installation And User Manual

Hide thumbs Also See for BladeCenter QS22:
Table of Contents

Advertisement

Note: To avoid problems and to maintain proper system performance, always make

Updating steps

Complete the following steps to update the BMC and system firmware images:
1. Check the revision level of the firmware on the blade server and the level of the
2. Download the firmware updates.
3. Power off the blade server you wish to update.
4. Update the BMC firmware using the BMC update package or the Advanced
5. Power on the blade server. This boots it with the new BMC firmware.
6. Update the system firmware image. See "Installing the system firmware" on
7. The system reboots. This boots the blade server with the new system firmware.
8. Shut down the blade server.
Note: There may be instances where you must update the BMC firmware before

Determining current blade server firmware levels

Complete the following steps to view the current firmware code levels for both the
BMC and the system firmware:
1. To check the BMC firmware level, access and log on to the Advanced
2. From the Monitors menu section, select Firmware VPD:
44
BladeCenter QS22 Type 0793: Installation and User's Guide
sure that both the BMC firmware and the system firmware are at the same
level for all QS22 blade servers within the BladeCenter unit.
updates on http://www.ibm.com/support/us/en/. If the level on the Web site is
higher than the version currently installed, continue with the updating steps.
Management Module. See "Updating the BMC firmware" on page 45 for further
information.
page 47 for further information.
updating the system firmware. Check the readme file that comes with each
firmware package for more information.
Management Module Web interface as described in the Management Module
User's Guide.

Advertisement

Table of Contents
loading

This manual is also suitable for:

0793

Table of Contents