Environmental Specifications - Intermec IV6 Quick Start Manual

Portable reader
Hide thumbs Also See for IV6:
Table of Contents

Advertisement

RFID Performance
RFID Tag Depth of Field
The read range is dependent upon the type of tag and the trans-
mitted output power, besides many other factors. The tag rates
contained in this document are what could be expected using a
theoretical free-space dipole tag at 915 MHz under U.S. FCC
Part 15 rules and regulations.
Typical Read and Write Range
S Read Range: 6-10 feet
S Write Range: Writing distances are 60% of the read distance
under the same conditions.

Environmental Specifications

Operating Temperature
Storage Temperature
Thermal Shutdown
Thermal Cycle
Thermal Shock
Non Operating
Humidity, Storage and Op-
erating
Moisture Resistance
Dust Resistance
UV Radiation
Solar
Quasi-Random Vibration
Shock
Vibration
Mechanical Shock
8
-20°C to + 55°C (-4°F to +131°F)
-30°C to +70°C (-22°F to +158°F)
70°C (158°F) measured on the power amplifier
-20°C to + 50°C (-4°F to +122°F) ramp 5°C/
min.
-30°C to +70°C (-22°F to +158°F)
ramp 30°C/min.
5% to 95% PH Non-condensing
IP65 Compliant
IP65 Compliant
ETSI EN 300 019-1-4 Class 4E
ETSI EN 300 019-1-4 Class 4E
Quasi-Random 20 G's RMS for 4 hours.
10g, 11ms, 1/2 Sin, (operating)
1.0 GRMS., 10 to 500 Hz, 3 axis (operating)
10 G, 11 msec, half sine pulse (operating)
IV6 Portable Reader