Intermec EasyCoder 201 II – Technical Manual
INTERFACES, cont'd.
Parallel Interface Board,
cont'd.
Intermec offers a 3 metres (9.8 ft.) long
ready-made parallel communication
cable (36-p male Centronics – DB25
male).
Part No. 1-010001-00
Connector configuration
The connector is the standard female 36-pole Centronics type. The
mounting holes are connected to chassis ground.
Pin
Signal
Dir.
1
/STROBE In
2
DATA 0
In
3
DATA 1
In
4
DATA 2
In
5
DATA 3
In
6
DATA 4
In
7
DATA 5
In
8
DATA 6
In
9
DATA 7
In
10
ACK
Out
11
BUSY
Out
12
PE
Out
13
SELECT
Out
14–15
16–17
GND
18
+ 5V
Out
19–30
GND
31
/INPRM
In
32
/ERROR
Out
33–35
36
/SLCTIN
In
37–38
GND
Note:
The PE signal (Paper End) on pin 12 requires an error-trapping
routine to be included in the Intermec Fingerprint software, activat-
ing the
and
BUSY
READY
such a routine may be written:
10
IF (PRSTAT AND 4) THEN GOSUB 1000
20
IF (PRSTAT AND 4) = 0 THEN GOSUB 2000
. . . .
. . . .
. . . .
1000 BUSY4
1010 RETURN
2000 READY4
2010 RETURN
Also see
and
BUSY
READY
Intermec Fingerprint manuals.
Remarks
See note!
not used
If strap fitted on P-2. Max. 200 mA.
not used
Housing
statements. Here is an example on how
statements and
PRSTAT
function in the
90

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents