IP
Input trigger (set using the RP command)
FL
Flags (set using the RE command)
CS
Rating of the light (after SafeSense has suc-
cessfully completed sensing the light)
RA
Rating of the light (set using the VL command).
When using Ethernet, use the following forms of the ST
command:
ST0
Reports the general settings. A typical output is:
TM 1, TP 20.00ms
STc
Where:
c = the input channel (1 to 2, 4, or 8 depending on model).
This reports the settings for a single channel.
Simulate an Input Trigger
TRc
Where:
c = the input channel (1 to 2,4 or 8, depending on model).
This simulates a trigger pulse. If the channel is in pulse mode it
pulses the output once.
Enable Ethernet Messages
GTm
Where:
m = 0 to disable Ethernet messages, or
m = 1 to enable Ethernet messages.
When Ethernet messages are enabled, any error reports are sent
to the most recent UDP or TCP address from which a command
has been received. Messages are of the form:
Evtc,e
Where:
= the channel number (1 to 2,4 or 8), or 0 for no channel
c
= event value (see
e
RTxxx LED lighting controllers - User Manual
Section 13.5, Event
—
59
—
codes).