The permitted range of values for pulse delay, pulse width, and
retrigger time is given in
limited by the operating conditions of the light.
Follow the keystrokes below to enter numerical data into the RT200
using the above scheme:
RTxxx LED lighting controllers - User Manual
Number
Range of values
format
Values are displayed in
9.99
seconds from 10ms to 5s in
steps of 10ms.
Values are displayed in
999.
milliseconds from 1ms to
999ms in steps of 1ms.
Values are displayed in
99.9
milliseconds from 0.1ms to
99.9ms in steps of 0.1ms.
Values are displayed in
milliseconds from 0.01ms
9.99
to 9.99ms in steps of
0.01ms.
Values are displayed in
999.
microseconds from 1μs to
999μs in steps of 1μs.
Section 13, Reference
E-2 is displayed. Press the
SEL  button to enter time values
from 10ms to 5s.
Use the p and q buttons to select
the required value in steps of
10ms. Press the SEL  button.