Checking operations
Use the CLI of the EM serial console or the EM console to check whether modules installed in the
Blade Enclosure are operating or not.
Switch module/pass-through card
1.
Check that the EM card is powered on.
2.
Check that you are logged on the CLI of the EM serial console or the EM console. If you are
not, log on.
Run the following command from the CLI. For details, see "Command specifications" in the
3.
User‟s Guide of the Blade Enclosure.
Checking the status of switch modules
Checks the status of switch modules:
SHOW SWITCH STATUS
If "Failed" is displayed, check to see whether the module is installed in the appropriate
slot. If the module is installed in the appropriate slot, try restarting the module. If the
failed status persists after restart, replace the module.
69