6. Maintenance

6.1 General Maintenance

6.1 General Maintenance
6.1 General Maintenance
The DC Fast Charger is cooled by forced air. Please keep charger in a ventilated
location and do not block the air vents of the DC Fast Charger .
Please clean or replace the air filters regularly to ensure the DC Fast Charger
works properly.
The housing was made of welding process and surface painting. It is necessary
to keep the exterior clean all the time. It ' s easy to get rusty if not keeping the ex -
terior clean especially in corrosion sensitive environment. Slightly rusty will not
affect charger performance, but if charger is serious rusty during or exceed the
warranty period, please contact local vendor for instruction.
Clean the DC fast Charger at least three times a year, keep the exterior clean at all
times.
Clean the outside of the cabinet with damp cloth or wet cotton towel, only use
low-pressure tap water and cleaning agents with PH level between 6 to 8.
Do not apply high-pressure water jets.
Do not use cleaning agents with abrasive components and do not use abrasive
tools. Improper cleaning agents might spoiled coating, painting, surface, bright -
ness and durability of all exterior parts.
If there is water intruding into the DC Fast Charger then please cut off the power
source immediately and contact the DC Fast Charger provider for repair.
Please make sure the charging connector is returned to the holder of the
charging connector after charging to prevent damage.
If there is damage to the charging connector, charging cable or holder of the
charging connector then please contact the DC Fast Charger provider.
When using the DC Fast Charger please handle properly. Do not strike or scrape
the cabinet or touch screen.
If the enclosure or screen is broken, cracked, open or shows any other indication
of damage then please contact the Standalone DC Fast Charger provider.
WARNING:
panelboard or load center before working on the equipment or remov -
ing any component. Do not remove circuit protective devices or any
other component until the power is turned OFF.
Disconnect electrical power to the DC Fast Charger before any maintenance work
to ensure it is separated from the supply of AC mains. Failure to do so may cause
physical injury or damage to the electrical system and charging unit.
Danger of electrical shock or injury. Turn OFF power at the