CLEARANCES — CGI603D MODELS
H
A
f
g
i
C

CLEARANCE DIMENSIONS

A Minimum clearance from top of trivets to:
Rangehood
z
Overhead exhaust fan
z
Downward facing combustible surface*
z
Downwards-facing tiled or fire resistant surface
z
B Minimum clearance below bench top to:
Combustible surface
z
Fisher & Paykel oven or nearest non-combustible surface
z
C Minimum clearance from side of cutout to nearest adjacent combustible surface
D Minimum distance from right edge of cooktop to gas connection point on wall
(if using a flexible hose)
E Distance from floor to gas connection point on wall
(if using a flexible hose)
F Minimum clearance from countertop to overhead cabinet
(not directly above the cooktop)
G Maximum depth of overhead cabinetry
H Minimum distance between overhead cabinets
(centered above cooktop)
I Minimum clearance from rear edge of cutout to nearest:
Combustible surface
z
Non-combustible surface
z
Ensure there is an earthed power outlet within 900mm of the centre rear of the product. The gas
connector on the wall should be accessible with the product installed.
*Combustible surface definition
Any materials of a building structure or decorative structure made of wood, compressed paper,
plant fibres, vinyl/plastic or other materials that are capable of transferring heat or being
ignited and burned. Such material shall be considered combustible even though flame-proofed,
fire-retardant treated or surface-painted, or plastered.
CGI603D
MM
650
800
650
500
70
65
115
250
800-850
450
600
600
85
45