Fisher & Paykel CGI905DNGTB4 Installation Manual page 17

Combi: gas + induction minimal cooktop
Table of Contents

Advertisement

NATURAL GAS MODELS
NG Models
LPG Models
manual shut-off valve
'open' position
to cooktop
gas supply line
Adjust to obtain a test point pressure of 1kPa with
the burner operating at the highest setting.
LPG MODELS
Adjust to obtain a test point pressure of 2.75kPa
with the burner operating at the highest setting.
ALL MODELS
Ensure the connection point will be accessible with
z
the installed cooktop.
Use an isolating valve close to the cooktop.
z
If connecting the gas with a flexible hose:
Ensure the hose is long enough to allow for removal
z
of cooktop for servicing.
Ensure the connection is located as shown in
z
'Clearace dimensions'.
The hose assembly must be AS/NZ 1869 Class
z
B or D certified, with an Rp 1/2" (ISO7-1) female
thread connection.
Note the replacement date on hose if applicable.
z
The hose assembly must not be longer than 1.2m
z
in length with minimum internal diameter of 10mm
and comply with relevant AS 5601/NZS 5261
requirements.
Ensure the hose is not kinked, and not subjected to
z
abrasion or permanently deformed.
Ensure the hose is not near or in contact with any
z
hot surfaces (eg base of metal hotplate, flue, or
chassis of underbench oven, etc).
GAS CONNECTION
GAS
ON
Manual shut-off valve
Ensure all dials are set to
z
After final gas connection is made, turn gas supply on and test all connections in gas
z
supply piping for gas leaks with a soapy water solution.
In order to avoid property damage or serious personal injury, never use a match or open
z
flame. If a leak is present, tighten joint or unscrew, apply more joint compound, tighten
again and retest connection for leak.
LEAK TESTING
Leak test points
before connecting cooktop to gas supply.
OFF
17