LEAB Automotive GmbH
PP101 - Sealed gel lead-acid
Fig. 11: Charging characteristic PP101
In the range [-30 °C ... -35 °C] and [+45 °C ... +50 °C] the current is reduced to 0.
NOTE! This charging characteristic contains a detection for weak batteries:
0.5 V per cell. Make sure that you do not charge batteries with a smaller num-
ber of cells. For example, do not charge a 12 V battery with a 24 V charging
characteristic.
Voltage per cell
2.35 V/2.26 V
LEAB Automotive GmbH
12 V system
14.1 V/13.56 V
Thorshammer 6
15 Appendix
24 V system
28.2 V/27.12 V
24866 Busdorf
27