10 Installation
Pin
Description
14
LED red (-)
18
CBL relay contact, normally open
19
Remote input (+)*
20
Voltage sensor (-)
22
LED (-)
25
Insulated 5 V (50 mA) output (+)*
26
CBL input
*The CAN bus signals, CBL, the remote input and the insulated 5 V output are
galvanically isolated from the DC output.
NOTE! Pins that are not listed are not assigned.
External LED Connection
The LED shows the charge status of the battery.
To connect the external LEDs, proceed as follows:
1. Connect the wire ends of the external LEDs to pin 4, pin 5, pin 14 and pin 22.
ð The external LEDs are connected.
EBrix Connection (24 V)
You can connect the RBC 24 V charger to the eBrix system using a suitable ad-
apter.
NOTE! Note that the RBC 24105 with part number 101036095 cannot be con-
nected to an eBrix.
CBL Control Relay Connection
A potential-free changeover contact is integrated in the RBC chargers, which
switches during charging operation. This option can be used, for example, to
implement an electrical start interlock with 230 V connection or charge monit-
oring.