Appendix - LEAB RBC 1280 User Manual

Hide thumbs Also See for RBC 1280:
Table of Contents

Advertisement

15 Appendix

15 Appendix
Charging Characteristics
NOTE! To select the correct charging characteristic for your battery, refer to
the instructions of your battery manufacturer.
NOTE! The current, compared to the nominal capacity, is given in coulombs
(C), e.g. 0.2 C for a 100 Ah battery results in 20 A.
LK10-05 - Freely ventilated lead-acid
Fig. 6: Charging characteristic LK10-05
In the "Top-Fill" charging phase, the battery is charged with +15% more current
compared to the main charging phase.
In the range [-30 °C ... -35 °C] and [+45 °C ... +60 °C] the current is reduced to
0.
Voltage per cell
2.4 V/ 2.8 V/ 2.29 V
22
LEAB Automotive GmbH
12 V system
14.4 V/ 16.8 V/ 13.74 V
Thorshammer 6
LEAB Automotive GmbH
24 V system
28.8 V/ 33.6 V/ 27.48 V
24866 Busdorf

Advertisement

Table of Contents
loading

Table of Contents