3.
INSTALLATION

3.1 ROOM NECESSARY FOR MACHINE USE

The machine must be installed in such a way that air can freely circulate all around its sides.
Enough room must be left free around the machine, in order to enable the operator to act without
constraint and also to immediately leave working area, if necessary.
The minimum access space to working area should be at least 150 cm. (60 in), which takes into
account the space taken up by open doors, if any.
15 cm (6 in)

3.2 WATER SUPPLY CONNECTION

The machine must be connected to the mains water, which must not exceed a pressure of 5 bar
72 PSI.
In water-cooled machines water connections (for machine wash and gas cooling) are placed on
rear panel.
3.3 MACHINE WITH AIR-COOLED CONDENSER
Machines with air-cooled condenser must be installed at least 50 cm (20 in) away from the back
wall in order to allow free air circulation around the condenser.
NOTE:
An insufficient air circulation affects operation and output capacity of the machine.
10 cm (4 in) water-cooled vers.
50 cm (20 in) air-cooled vers.
15 cm (6 in)
150 cm (60 in)