Optional: Activate Switch-Off Function - LEAB CDR 12/24 V User Manual

Battery isolator
Hide thumbs Also See for CDR 12/24 V:
Table of Contents

Advertisement

LEAB Automotive GmbH
To change the direction of the charging current distribution to bidirectional,
carry out the following step:
2 Disconnect the connection cable from plug contact PIN 2.
ð The charging current distribution is bidirectional from screw terminal 1 to
screw terminal 2 or vice versa, depending on where a higher voltage is
present.

7.4 Optional: Activate switch-off function

The CDR can be switched off manually (permanently OFF) to prevent overchar-
ging of a fully charged lithium-ion battery. The device can therefore be used
as an automatic cut-off relay to connect/disconnect a consumer or an on-
board supply system.
NOTE! The disconnection is independent of the direction of the charging cur-
rent selected.
To activate the function, perform the following step:
1 Switch the plug contact PIN 3 to ground.
ð The function is activated. The device is switched off.
LEAB Automotive GmbH
Thorshammer 6
7 Installation
24866 Busdorf
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

1072001001

Table of Contents