APPENDIX A: TECHNICAL SPECIFICATIONS
Mode Selection Settings for Each Weld Schedule (continued):
Feedback Gain Adjustment (C-GAIN=) . . . . . . . . . . . . . . . . . . . . . . . IP-215A: (0) - (9)
Data Output (D-OUT=) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (OFF)/(ON)
I/O Signal Connector Functions:
NOTE: Please refer to Appendix B for signal specifications.
Input Signals: 5 normally open contacts – START 1 - START 4 and TROUBLE RESET
Mechanical Relay Output Signals . . . . . . . . 2 normally open contacts – END OUTPUT
Transistor Output Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . COUNT END OUTPUT
DATA Connector Function (Optional Connector) . . . . . . . . . . . . . RS-485 Protocol Data Port
Welding Transformer Compatibility:
NOTE: Please refer to Appendix C for welding transformer specifications.
IP-215A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IT-500A, IT-501A
IP-217A . . . . . . . . . . . . . . . . . IT-500A, IT-501A, IT-510A, IT-511A, IT-512A, IT-540A
Welding Transformer Selection Interval Time,
Multiple Weld Head Operation . . . . . . . . . . . . . . . . . . . 10 to 990 msec in 10 msec increments
Welding Transformer Selection Channels, Multiple Weld Head Operation . . . . . . . . . . 0 - 4
Welcard Schedule Card Capacity . . . . . . . 91 weld schedules (7 schedules, 13 files/schedule)
Welcard Monitor 1 Card:
Parameters Stored . . . . . . . . . Start No., Step No., Current 1 and Current 2 values, Time
Number of Parameters Stored (max) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3,584
Welcard Monitor 2 Card:
Parameters Stored . . . . . . . . . . . . . . . . . . . . . . . . Start No., Monitored Current ±%, Time
Number of Parameters Stored . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7,168
Welcard Battery Back-Up:
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lithium BR2016
Service Life (minimum) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Years
IP-215A/217A FINE SPOT WELDING POWER SUPPLIES
A-4
IP-217A: (0) - (5)
and TROUBLE OUTPUT
993-603 REV A: October, 1996