Table 6-1. Welcard Error
Display Message
?? CARD IS NOT SET!!
? FILE F [XX] HAS
ERROR!!
? FILE F [XX] HAS NO
DATA!!
FXX [ ] NOT RECORDED
FXX [
]* COPY
IMPOSSIBLE !!
FXX [
] ERASE?
YES
NO
COPY FROM MONITOR
CARD IMPOSSIBLE!!`
IP-215A/IP-217A FINE SPOT WELDING POWER SUPPLIES
993-603 REV A: October, 1996
CHAPTER 6: USING THE WELCARD
Messages (continued)
Probable Cause
The card is not properly
installed in its slot.
An error has been found in
the card copying operation.
In the card to Power Supply
copy direction, the specified
file contains no data.
When the directory is
referenced, the specified file
contains no data.
During data copying from
the Power Supply to a card,
the specified file is found to
be write-protected.
During data copying from
the Power Supply to a card,
the specified file is found to
already exist.
Card copying is selected but
a Monitor Card is installed.
Remedy
Install the card properly.
Attempt the copy operation
again. If not successful, there
is a Power Supply failure or
the card is defective. Contact
the factory.
Specify a file containing data.
Use a card that has data
recorded.
Cancel file write protection.
(Refer to Referencing the
Directory in this chapter.)
To copy, select YES and
press ENTER.
To cancel, select NO and
press ENTER.
Replace the Monitor Card
with a Schedule Card or
reinitialize the installed card
as a Schedule Card.
6-7