CHAPTER 5: OPERATING YOUR POWER SUPPLY
Display Screen Field
Weld 1 Current Rise (R1)
Weld 1 (W1)
Cool Time (CO)
Weld 2 Current Rise (R2)
Weld 2 (W2)
CURR 1. or CURR. 2:
Constant Current Control (215)
Constant Voltage Control (215)
Constant Power Control (215)
Constant Current Control (217)
Constant Voltage Control (217)
Constant Power Control (217)
*If the IT-500A Welding Transformer is selected and the current setting
exceeds 2.01KA, a current setting error will occur.
Transformer Model
Feedback Gain (C—GAIN=)
Welding Transformer Channel Programming (SCAN Key)
Scan Count
Scan Interval Time
Table 5-1. Display Data Entry Ranges (continued)
IP-215A/IP-217A FINE SPOT WELDING POWER SUPPLIES
5-2
Table 5-1. Display Data Entry Ranges
Weld Schedule (WELD SCHED. Key)
Mode Selection (MODE Key)
Setting Range
0 - 49
00 - 99
00 - 99
0 - 49
00 - 99
0.20 - 2.00
0.20 - 2.00
0.40 - 4.00
0.40 - 4.00*
0.4 - 4.00
0.16 - 9.99
IT-500A (215, 217)
IT-501A (215, 217)
IT- 510A (217)
IT-511A (217)
IT-512A (217)
0 - 9 (215)
0 - 5 (217)
0 - 4
0 - 990
993-603 REV A: October, 1995
Unit
msec
msec
msec
msec
msec
KA
V
KW
KA
V
KW
Model No.
Model No.
Model No.
Model No.
Model No.
Units
Units
Units
msec