Installing Splashguards - Hussmann Impact F6 Installation And Operation Manual

Multi-deck frozen food wall merchandiser
Hide thumbs Also See for Impact F6:
Table of Contents

Advertisement

3-2
DRIP PIPING AND SPLASHGUARDS
5. Provide a suitable air break between
flood rim of the floor drain and out-
let of drip pipe. To meet code on
low base merchandisers, it may be
necessary to install a field-supplied
drip pipe reducer. An alternative is
to cut the last section of drip pipe at
an angle.
6. Prevent drip pipes from freezing:
A. Do NOT install drip pipes in contact with
uninsulated suction lines. Suction lines should
be insulated with a non-absorbent insulation
material.
B. Where drip pipes are located in dead air
spaces, such as between merchandisers or
between a merchandiser and a store wall, pro-
vide means to prevent freezing.

INSTALLING SPLASHGUARDS

The splashguard and brackets are shipped inside
each case.
Install splashguard brackets before piping case.
Use two screws per bracket; attach brackets every
4 ft (1219 mm) at pre-drilled locations.
After merchandisers have been leveled and joined,
and all drip piping, electrical and refrigeration
work has been completed, install the splashguard.
To Install Splashguards:
1. Check to be sure that all splashguard brackets
are level with the floor.
2. Position top of splashguard over the top edge
of the bracket as shown below.
3. Push the lower edge of the splashguard toward
the bottom of the bracket until it snaps into
place.
P/N 0416183C