The Periorbital Tip

The second configuration of the Tip is the periorbital Tip. It is made of the same materials and is designated
for treatment of hard-to-reach locations, such as the periorbital area. It has the same design as the standard
Tip, except for its size: the treatment surface 6 × 4 pyramids (24 in total) and its active area (the area of
the matrix of pyramids) is 0.3 cm².
Tip Description -General Specifications and Operating Parameters
Size (Height, Length, Width -
approximated)
Working temperature
Hibernation temperature
Pulse duration
Pulse protrusion
Maximal allowed number of
pulses per Tip
Initial complimentary pulse
credit
Page | 16
 
Tip€31
s Treatment
Surface
Standard Novoxel
Standard: H 6.5mm X L15mm X W15mm
Periorbital: H 13mm X L15mm X W15mm
400°C (+5°C/-15°C)
200°C (±5°C)
5-18 milliseconds (±1millisecond)
(Possible durations: 5,6,8,10,12,14,16,18;
Possible durations for double pulse: 6-16)
100-1,000 µm (microns), intervals of 100 µm
250,000
25,000 for any new Tixel2 device HP (regard-less of Handpiece and Tip
types)
®