Vega VEGABAR 87 Operating Instructions Manual page 61

Submersible pressure transmitter with metal measuring cell
Hide thumbs Also See for VEGABAR 87:
Table of Contents

Advertisement

Nominal range
0 ... 25 bar/0 ... 2500 kPa
Nominal measuring ranges and overload capacity in psi
Nominal range
Gauge pressure
0 ... +1.5 psig
0 ... +5 psig
0 ... +15 psig
0 ... +30 psig
0 ... +150 psig
0 ... +300 psig
Absolute pressure
0 ... 15 psi
0 ... 30 psi
0 ... 150 psi
0 ... 300 psi
Adjustment ranges
Specifications refer to the nominal measuring range, pressure values lower than -1 bar cannot be
set
Min./Max. adjustment:
Ʋ Percentage value
Ʋ Pressure value
Zero/Span adjustment:
Ʋ Zero
Ʋ Span
Ʋ Difference between zero and span
Max. permissible Turn Down
Switch-on phase
Start-up time with operating voltage U
Ʋ ≥ 12 V DC
Ʋ < 12 V DC
Starting current (for run-up time)
Output variable
For details on the operating voltage see chapter "Voltage supply"
VEGABAR 87 • 4 ... 20 mA/HART
Maximum pressure
25 bar/+2500 kPa
Maximum pressure
+225 psig
+360 psig
+360 psig
+360 psig
+360 psig
+360 psig
360 psi
360 psi
360 psi
360 psi
-10 ... 110 %
-20 ... 120 %
-20 ... +95 %
-120 ... +120 %
max. 120 % of the nominal range
Unlimited (recommended 20 : 1)
B
≤ 9 s
≤ 22 s
≤ 3.6 mA
11 Supplement
Overload capability
Minimum pressure
0 bar abs.
Overload capability
Minimum pressure
-14.51 psig
-14.51 psig
-14.51 psig
-14.51 psig
-14.51 psig
-14.51 psig
0 psi
0 psi
0 psi
0 psi
61

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vegabar 86

Table of Contents