Vega VEGABAR 87 Operating Instructions Manual page 23

Submersible pressure transmitter with metal measuring cell
Hide thumbs Also See for VEGABAR 87:
Table of Contents

Advertisement

Connection compartment
Supplementary electron-
ics - Additional current
output
VEGABAR 87 • 4 ... 20 mA/HART
Fig. 15: Connection compartment - double chamber housing
1
Voltage supply, signal output
2
For display and adjustment module or interface adapter
3
For external display and adjustment unit
4
Ground terminal for connection of the cable screening
To make a second measured value available for use, you can use the
supplementary electronics " Additional current output".
Both current outputs are passive and need a power supply.
Fig. 16: Terminal compartment, double chamber housing, supplementary elec-
tronics " Additional current output"
1
First current output (I) - Voltage supply and signal output, sensor (HART)
2
Additional current output (II) - Voltage supply and signal output (without
HART)
3
Ground terminal for connection of the cable screening
5 Connecting to power supply
4...20mA
+
1
2
( )
(-)
1
I
4...20mA
+
1
2
( )
(-)
3
1
2
3
Display
5
6 7 8
4
I I
4...20mA
+
7
8
( )
(-)
2
23