11 Supplement
Connection cable with IP68 (25 bar) version
Ʋ Cable cover
Ʋ Type label support on cable
Materials, transmitter protection
Transport and mounting protection
transport protection net
Weights
Basic weight
Suspension cable
Connection tube
Straining clamp
Threaded fitting
Torques
Max. torque for process fitting
Ʋ G1½
Max. torque for NPT cable glands and Conduit tubes
Ʋ Plastic housing
Ʋ Aluminium/Stainless steel housing
Input variable
The specifications are only an overview and refer to the measuring cell. Limitations due to the
material and version of the process fitting as well as the selected pressure type are possible. The
specifications on the nameplate apply.
Nominal measuring ranges and overload capability in bar/kPa
Nominal range
Gauge pressure
0 ... +0.1 bar/0 ... +10 kPa
0 ... +0.4 bar/0 ... +40 kPa
0 ... +1 bar/0 ... +100 kPa
0 ... +2.5 bar/0 ... +250 kPa
0 ... +10 bar/0 ... +1000 kPa
0 ... +25 bar/0 ... +2500 kPa
Absolute pressure
0 ... 1 bar/0 ... 100 kPa
0 ... 2.5 bar/0 ... 250 kPa
0 ... 10 bar/0 ... 1000 kPa
Between transmitter and external electronics housing.
5)
Data on overload capability apply for reference temperature.
6)
60
5)
PE, PUR
PE hard
PFA
PE
0.7 kg (1.543 lbs)
0.1 kg/m (0.07 lbs/ft)
1.5 kg/m (1 lbs/ft)
0.2 kg (0.441 lbs)
0.4 kg (0.882 lbs)
200 Nm (147.5 lbf ft)
10 Nm (7.376 lbf ft)
50 Nm (36.88 lbf ft)
6)
Maximum pressure
+15 bar/+1500 kPa
+25 bar/+2500 kPa
+25 bar/+2500 kPa
+25 bar/+2500 kPa
+25 bar/+2500 kPa
+25 bar/+2500 kPa
25 bar/+2500 kPa
25 bar/+2500 kPa
25 bar/+2500 kPa
Overload capability
Minimum pressure
-1 bar/-100 kPa
-1 bar/-100 kPa
-1 bar/-100 kPa
-1 bar/-100 kPa
-1 bar/-100 kPa
-1 bar/-100 kPa
0 bar abs.
0 bar abs.
0 bar abs.
VEGABAR 87 • 4 ... 20 mA/HART