No.
E 210
Line too long.
E 211
Nested repeat is not supported.
E 212
Loop number invalid.
E 213
File too long.
E 214
Statement 'repeat <num. rep.>' missing.
E 215
Command not found
E 216
Download file name missing.
E 217
Opening download file failed.
E 218
Upload file name missing.
E 219
Opening parameter file for upload failed.
E 220
Opening upload file failed.
E 221
Command not allowed in script file.
E 222
Processing a command failed.
E 223
Command execution failed.
E 300
Determining download directory failed.
E 301
Determining upload directory failed.
E 302
Trying to open USB port failed.
E 303
Trying to connect Programmer failed.
E 304
Trying to open serial port failed.
E 305
Changing the communication speed of the
programmer failed.
E 306
Trying to connect Programmer failed.
E 307
Trying to open USB failed.
E 316
Trying to connect Programmer failed.
E 317
ver command failed.
E 400
Port is already open.
E 401
The communication port has not been opened so
far.
E 500
Evaluating CRC answer failed.
E 501
Operation failed.
E 502
Programmer is not responding.
E 503
Receiving failed.
E 600
Appending information to communication logging
file failed.
112
CHAPTER 10 ERROR MESSAGES
Message
User's Manual U15260EJ3V1UM
Description
Executing a script file might abort with one of these errors.
The contents of the line causing the error are also
displayed.
The script syntax was correct and the command has been
sent to the PG-FP4, but the command execution itself
showed an error (e.g. a verify error on the target device).
The selected directory name in the file download dialog
box is invalid.
The selected directory name in the file upload dialog box is
invalid.
The processing after setting the Programmer
Communication Setup dialog box might fail due to one of
these reasons. Please verify proper selection of the
port/speed for the programmer.
Executing the ver command failed.
Processing after setting the Programmer Communication
Setup dialog box failed since the port is already open.
Check if programmer ports are set correctly.
Sending a command to the PG-FP4 is only possible after
the communication channel has been opened.
The PG-FP4 answered with an unexpected string after
sending the Checksum command.
Executing a command failed (e.g. a verify error occurred for
a signal from the target device).
Communication between the PC and the PG-FP4 timed out.
Reading the PC port failed.
Writing data to the communication log file failed.