5 Installation Procedure
Connecting the LCD Operator Option to the Drive
Plug the communication cable into the communication cable connector of the LCD Operator
Option and the drive communications port as shown in
are firmly connected.
for information regarding recommended cables.
Refer to
Table 1
for Built-in LED Display Behavior with a Connected LCD Operator
Option.
Note: Use only Yaskawa recommended cables. Using a cable not specified may cause the LCD
Operator or drive to malfunction.
Note: The STOP key on the drives built-in LED operator is the only functional key on the built-in LED
operator when the LCD Operator Option is connected to the drive and parameter b1-02 is set to
0 (LCD Operator Option). To disable the STOP key, set parameter o2-02 (STOP key Function
Selection) to 0 (Disable).
Figure 11
LED
Operator
V1000
24
Refer to Item Names and Part Numbers (Sold Separately) on page 11
Drive
STOP
周波数指令
:
(Hz)
正転逆転選択
:
(Hz)
出力周波数
:
(A)
出力電流
:
(V)
出力電圧
:
モニタ
:
ベリファイ
:
セットアップ
:
パラメータ設定
:
オートチューニング
:
WARNING
Risk of electric shock.
Read manual before installing.
Wait 5 minutes for capacitor discharge after
disconnecting power supply.
To conform to
requirements, make sure
to ground the supply neutral for 400V class.
危 険
けが、感電のおそれがあります。
据え付け、運転の前には必ず取扱説明書を読むこと。
通電中および電源遮断後
5
分以内はフロントカバーを
外さないこと。
級インバータの場合は、電源の中性点が接地
400V
されていることを確認すること。(  対応)
Figure 11 Communication Cable Connection
YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual
Figure
LCD Operator Option
Comm Port
11. Ensure both cable ends
MODEL:JVOP-180
REV:A
PASSED
L/N
:BY1-00004
PRG:0100
S / N : J007XE273710001
YASKAWA ELECTRIC CORPORATION
MADE IN JAPAN
Communication Cable Connector