Internal/Flush-mount Installation
The internal flush-mount installation method requires an installation support that is
purchased separately.
page 11
for information regarding the installation support and mounting hardware.
illustrates how to attach the Installation Support A.
1.
Cut an opening in the enclosure panel for the LCD Operator Option according to
Figure 10
2.
Mount the LCD Operator Option to the installation support (sold separately).
3.
Mount the installation support and LCD Operator Option to the enclosure panel.
Figure 9
M4 × 10 (0.39)
Phillips truss head screw × 4
(for panel widths between 1 (0.04)
and 1.6 (0.06))
Note: For environments with a significant amount of dust or other airborne debris, use a gasket
between the enclosure panel and the LCD Operator Option.
Figure 10
Figure 10 Panel Cut-out Dimensions (Internal/Flush-mount Installation)
YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual
Refer to Item Names and Part Numbers (Sold Separately) on
.
Figure 9 Internal/Flush Mount Installation
45 (1.77)
+0.5
59
0
Enclosure panel
+0.02
(
2.32
)
Unit : mm (in)
0
5 Installation Procedure
LCD Operator Option
Installation Support A
M3 × 6 (0.24)
Phillips recessed pan head
machine screw × 2
Unit : mm (in)
Figure 9