ENGLISH
will be relieved automatically when cavity
temperature is lower than 280℃,door lock
icon "
" on the display screen will
extinguish at this time.(Refer to picture 9 for
display effect.)
Pic 8: Door lock activated display effect
under standby status
Pic 9: Door lock relieved display effect
under standby status
6.2 Oven will be locked under following
status:
• Among all function mode(except for de
frost mode),door lock will automatically be
activated when oven cavity temperature is
higher than 300℃.
• During self-cleaning process, door lock
will be activated.
EN 30
When oven is under standby mode, and
temperature sensor is open-circuit or short
circuit, door lock will be activated and
cooling fan still works, display effect will
be as picture 8 shown.
6.3 Oven will be unlocked under following
situations:
• When self-cleaning process is completed
or paused, oven door lock will automatically
be relieved only when oven cavity
temperature drops to below 280℃.
If electricity is cut off during self-cleaning
process, oven door will be unlocked only
after power on again. (Note: Even if power
on again, oven door will be automatically
unlocked only when cavity temperature is
below 280℃.)
• During other function mode working, if
oven temperature is abnormal, the oven door
will be relieved only when cavity
temperature is below 280℃.