Site requirements

INTRODUCTION

The Aga Cookmaster is a floor standing only cooker, fired by a gas burner. It is suitable for vertical flue outlet only.

IMPORTANT

The burner fitted to this appliance has been designed and constructed exclusively for use with the Aga
Cookmaster and MUST not be used on any other appliances or any other uses.

GAS SUPPLY

Installation Pipes
Pipework from the meter to the appliance must be of adequate size. Do not use pipes of a smaller size than the appliance
gas connection. To avoid undue stress on pipework and burner, adequate support should be used when connecting and
disconnecting union. The complete installation must be tested for soundness and purged in accordance with the
regulations in force.
NOTE: USE SOAPY WATER SOLUTION ON NEW GAS CONNECTIONS TO ENSURE THERE ARE NO GAS LEAKS.
Gas Supply Pipe - U.S. Pipe Threads
NOTE: A GAS CONTROL VALVE MUST BE INSTALLED IN THE GAS PIPELINE EXTERNALLY OF THE RANGE (NOT
SUPPLIED) FOR THE PURPOSE OF TURNING ON OR SHUTTING OFF GAS TO THE APPLIANCE. DO NOT FIT
VALVE BEHIND THE COOKER; IT MUST BE INSTALLED IN AN ACCESSIBLE LOCATION.
The appliance has a 10 mm (1/2") N.P.T. Male Connection at the front left hand side.
ALL GAS CONTROLS MUST BE U.S. PIPE THREADS.
Maximum Heat Input: 50,000 Btu/h Oven Only
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressure in excess of 1/2 psig (3.5 kPa). The appliance must be isolated from the
gas supply piping system by closing the individual manual shut-off valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
Leak testing of the appliance shall be conducted according to the manufacturers instructions.
FLUE SAFETY DEVICE
For safety purposes, a flue safety device is fitted. This will only operate in adverse flue conditions. If the switch has
operated, it should be pushed in only to reset. If this problem persists, it is necessary to determine and rectify the cause.
If it is found necessary to reset more than once, this may indicate a flue blockage.