Servicing Or Fault - Heartland Classic HL-CKNG Owner's Manual

Cookmaster
Table of Contents

Advertisement

Servicing or Fault

BURNER RESET
If a fault occurs on the burner, then it automatically shuts
down and the red button on the front base plate will be
illuminated. This can be reset, after 10 seconds by
depressing the reset button. The reset button is located in
the lower base panel.
OPERATING BY PRESSING WITH FINGER ONLY
Please wait at least 10 seconds between resetting the
lockout button. If resetting the lockout button does not light
the burner immediately, it will be necessary to repeat the
sequence.
Continued lockouts indicate a burner or gas supply
malfunction. This fault should be diagnosed and rectified.
In the event of repeated failure, close the gas valve and
disconnect electrical supply to the appliance and contact
your installer/service engineer.
FLUE SAFETY DEVICE
For safety purposes, a flue safety device is installed. This will
FLUE SAFETY
BURNER RESET
only operate under adverse flue conditions, If the switch has
DEVICE
BUTTON
been operated, it should be pushed into reset and the pilot
re-lit. If this problem persists contact your local engineer to
determine and rectify the cause. It is important not to reset
more than once as this may indicate a flue blockage.
FIG. 34
GAS LEAK OR FAULT
If a gas leak or fault exists or is suspected, the unit must be
isolated from the gas and electrical supply. The appliance
must not be used until the fault has been rectified.
Advice/Help should be obtained from your Installer/Servicing
Company.
POWER FAILURE
In the event of a short term power failure, the clock display
will disappear and then return on the power supply being
reinstated.
However if the power supply is interrupted for any length of
time, the clock display will be lost. Follow procedure 'TO SET
TIME'.
SERVICING
With normal use the cooker will need annual flueway
cleaning and burner maintenance, which should be carried
out by a qualified engineer.
A HOT APPLIANCE CANNOT BE SERVICED.
The cooker thermostat knob should be turned OFF the night
preceding the day of the servicing so that the appliance will
have cooled down by the following morning.
50

Advertisement

Table of Contents
loading

Related Products for Heartland Classic HL-CKNG

This manual is also suitable for:

Hl-cklp

Table of Contents