Gas Inlet
Electrical Supply
Appliance Inlet
Pressure (MAX.)
Burner Pressure
(NEGATIVE)
Max Flue Temp.
CO
CO
%
2
Heat Input

TECHNICAL DATA

1/2" NPT
115 V
60 Hz
Natural Gas
10" w.g.
-
0.044 w.g. (± 0.012" w.g.)
(non-adjustable)
445ÞF
0 - 50 ppm
8.2% - 9.9%
50,000 Btu/hr
PLEASE NOTE: IT IS ADVISABLE TO
CHECK THE ACTUAL SIZE/WIDTH
OF YOUR APPLIANCE BEFORE
FINALLY FIXING ANY KITCHEN
UNITS, SINCE ENAMELLED CAST
IRON CAN VARY IN SIZE
Unpacked Appliance Weight - 326 Kg (719 lbs)
Propane
15" w.g.
-
450ÞF
0 - 50 ppm
9.4% - 10.8%
50,000 Btu/hr
5
DIMENSIONS IN MM
0.044 w.g. (± 0.012" w.g.)
(non-adjustable)
DESN 512448