Installation Requirements; Clearances; Preliminary Installation - Heartland Classic HL-CKNG Owner's Manual

Cookmaster
Table of Contents

Advertisement

CLEARANCES

The appliance is floor mounted. The space in which the
appliance is to be fitted must have the following minimum
dimensions.
Between wall and LH side of appliance - 10mm (1/2")
Between wall and RH side of appliance - 10mm (1/2")
SHOULD THE WALL PROJECT BEYOND THE FRONT
OF THE APPLIANCE, THEN THE GAP AT THE R.H.
SIDE MUST BE INCREASED TO 50mm (2") TO ALLOW
REMOVAL OF OVEN SHELVES. SEE PAGE 4 - FIG. 1A.
Above the raised insulating cover handle - 60mm (3")
In addition, adequate clearance must be available at the
front of the appliance to enable it to be operated and
serviced.

PRELIMINARY INSTALLATION

The appliance is delivered in a fully assembled condition
with the exception of the following items which are
supplied separately packed and require assembly:
The appliance rear distance bracket.
The cooker handrail.
Appliance rear distance bracket: if the rear wall is of
combustible material, there must be an air gap of 25mm
(1") between the wall and the rear of the cooker. Fit the
rear distance brackets as shown in Fig. 3. Whenever
possible it is recommended that the skirting board is
removed for the width of the appliance to enable the rear
edge of the appliance top plate to make contact with the
vertical wall and avoid a rear gap. (Combustible wall
excepted).
Where the cooker is to stand in a recess or against a wall
which is to be tiled, IN NO CIRCUMSTANCES SHOULD
THE TILES OVERLAP THE TOP PLATE.
The handrail brackets are held on the front edges of the
cooker top-plate casting. Remove the travel nuts and
replace with the handrail brackets ensuring the fiber
protecting washers are in position. Insert the handrail with
fitted end caps into the brackets, positioning them
correctly, and tighten the locating bolts (Fig. 4).

Installation requirements

FIG. 3
FIG. 4
11
DESN 510226
DESN 510454 'A'