5.3 Cable list and minimum thickness
Connections
230/400V 3F power supply
230/400V 3F motor power supply
Flashing lamp
Photocell transmitters
Photocell receivers
power supply to accessories
Control and safety devices
Antenna connection
N.B.: if the cable length differs from that specified in the table, then you must determine the proper cable diameter in the basis of
the actual power draw by the connected devices and depending on the standards specified in CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power
draw and distances.
When connecting products other than those mentioned in this manual please see the documents provided with the products
themselves.
1) Right-hand gearmotor unit (MD gearmotor + CD foundation box)
2) Left-hand gearmotor unit (MS gearmotor + CS foundation box)
3) Cable box for connections
4) Control panel
5) Tuned antenna
6) Movement-indicating fl ashing lamp
7) Key-switch selector
8) Safety photocells
9) Branching pit
10) Drainage pit
11) Mechanical stops
6
5
4
9
Type of cable
Length of cable 1 < 10 m
4G x 1,5 mm
4G x 1 mm
FROR CEI
2 x 0,5 mm
20-22
2 x 0,5 mm
CEI EN
4 x 0,5 mm
50267-2-1
2 x 0,5 mm
2 x 0,5 mm
RG58
8
7
3
10
L. of cable 10 < 20 m L. of cable 20 < 30 m
2
4G x 2,5 mm
2
4G x 1,5 mm
2
2 x 1 mm
2
2 x 0.5 mm
2
4 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
max. 10 m
8
1
11
2
11
2
4G x 4 mm
2
4G x 2,5 mm
2
2 x 1,5 mm
2
2 x 0,5 mm
2
4 x 0,5 mm
2
2
2 x 1 mm
2
2 x 0,5 mm
3
11
2
2
2
2
2
2
5