CAME FROG J Installation Manual

In-ground operator for swing gates
Hide thumbs Also See for FROG J:

Advertisement

Quick Links

1 19AU 14 EN
IN-GROUND OPERATOR FOR SWING GATES
INSTALLATION MANUAL
FROG J
EN
English

Advertisement

Table of Contents
loading

Summary of Contents for CAME FROG J

  • Page 1 1 19AU 14 EN IN-GROUND OPERATOR FOR SWING GATES INSTALLATION MANUAL FROG J English...
  • Page 2: Read Carefully

    • Use this product only for the specifi c purpose for which it is designed. Any • Keep away from the hinges and any moving mechanical parts • Stay out other use is therefore improper and dangerous. CAME Cancelli Automatici of the operating range of the operator while it is moving • Do not oppo- S.p.A.
  • Page 3: Legend Of Symbols

    3 Reference Standards The company: CAME Cancelli Automatici S.p.A. is ISO 9001:2000 quality certified; is has also obtained the ISO 14001 environmen- tal safeguarding certification. Came engineers and manufactures all of its products in Italy. This product complies with the following standards: EN 12978, UNI EN 954-1, CEI EN 60335-1, UNI EN 12453.
  • Page 4: Description Of Parts

    4.3 Description of parts Gate pin-housing ring Gearmotor pin-housing ring Gearmotor mobile ring Endstop adjustment set screw Release group Cover Operator In-ground case Custom key for release group 4.4 Dimensions (mm) 5 Installation Installation must be carried out by expert qualified personnel and in full compliance with current regulations. 5.1 Preliminary checks Before installing, do the following: •...
  • Page 5: Tools And Materials

    5.2 Tools and materials Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance with the current standards and regulations. The following figure illustrates the minimum equipment needed by the installer. 5.3 Cable list and minimum thickness Connections Type of cable...
  • Page 6 5.5 Preparing for the foundation casing The following illustrations are only examples, given that the space available for anchoring the operator and accessories may vary from gate to gate. It is up to the installer, thus, to choose the most suitable solution. N.B: illustration view: left side, inside view.
  • Page 7: Installing The Unit

    5.6 Installing the unit N.B.: view of illustrations: outer side (to simplify the description of the mounting phases) - Insert the releases into the in-ground box and anchor them using the supplied screws. - Assemble the transmission arm with the pin-housing ring to the stuffi ng box, anchor them using the (M6x16) set screws and nuts. Warning: the threaded holes for inserting the (m10x90) adjustment set screw of the gate pin-housing ring is to be positioned opposite the threaded hole of the gearmotor pin-housing ring.posizionato dalla parte opposta al foro fi...
  • Page 8 - Mount the gate leaf by only inserting the top hinge. Check that the gate leaf opens and closes easily. Bolt into place using the proper bolts or carefully weld the gate leaf to the transmission arm. - Insert the gearmotor into the in-ground box and anchor it using bolts and washers.
  • Page 9: Adjusting The Mechanical Endstops

    - Set the lever of the release group to the gearmotor. 5.7 Adjusting the mechanical endstops - Before tightening the set screws to adjust the opening and closing of the gate, release the gearmotors (see paragraph for manual releasing). Procedure for adjusting the closing: turn the M10x90 (1) set screw clockwise or counter clockwise; lock the nut so that it is opposite the thread (2).
  • Page 10 - After making the necessary adjustments and electrical connections (see following chapter), place the cover onto the box and screw it down using the supplied cylinder-head screws. Ø4,8x19 5.8 Manual release and blocking of the gearmotor Release procedure: - Raise the protective cover of the blocking mechanism and insert the key. Turn the release handle 90° counter-clockwise. - Close the door before manually moving the gate leaf.
  • Page 11 Re-blocking procedure: - Raise the protective cover of the blocking mechanism. Turn the release handle 180° clockwise and close the small door. - Turn 90° counter-clockwise, remove the key and close the small door.
  • Page 12: Connecting To The Control Panel

    6 Connecting to the control panel When making electrical connections, use the pit the shunt boxes. For further instructions concerning functions and adjustments, consult the control panels technical documentation. Control panel Left gearmotor Right gearmotor Shunt box Junction pit ZL90 Control panel BLUE BROWN BLACK...
  • Page 13: Maintenance

    7 Maintenance Periodic maintenance Before doing any maintenance, cut off the power supply, to prevent any hazardous situations caused by accidentally activating the operator. ☞ Periodic maintenance log kept by users (every six months) Date Notes Signature Extraordinary maintenance The following table is for logging any extraordinary maintenance jobs, repairs and improvements performed by specialized contractors. ...
  • Page 14: Troubleshooting

    CAME CANCELLI AUTOMATICI S.p.A. employs a UNI EN ISO 14001 certified and compliant environmental protection system at its plants, to ensure that environmental safeguarding. We ask you to keep protecting the environment, as CAME deems it to be one of the fundamental points of its market operations strategies, by simply following these brief guidelines when disposing: DISPOSING THE PACKING MATERIALS The packing components (cardboard, plastic, etc.) are solid urban waste and may be disposed of without any particular difficulty, by...
  • Page 16 HR • Za sve dodatne informacije o poduzeću, proizvodima i tehničkoj podršci: UK • Для отримання будь-якої іншої інформації про компанію, продукцію та технічну підтримку: www. came.com www. came.com CAME Cancelli Automatici S.p.a. CAME Cancelli Automatici S.p.a. Via Martiri Della Libertà, 15 31030 Dosson Di Casier...